38 | alemite Carbon Shield Service Guide
WWW.ALEMITECARbONSHIELD.COM
troubleshooting chart
Problem
Possible cause
Possible solution
Not enough mist being
produced
1. Reduced oil supply
resulting in lean oil
to air mixture.
1.1 Pull the relief valve ring. visually inspect
mist quality. Good mist should resemble
smoke with no oil condensation visible.
1.2 Check oil level in the reservoir; verify oil
level is in the operating range. verify oil
consumption rate from the HMI.
1.3 Confirm oil adjustment screw has
not been changed from factory setting.
Adjust if needed. If change occurred
in this setting, it will be time stamped
in the alarm log.
1.4 Check oil suction screen for obstruction.
2. Oil or Air Heater
Malfunction.
2.1 Confirm oil and air temperature. Factory
default is 100 °F (37.8° C).
2.2 Check fuses F1, F2, F9 and F10, and
relays R0 and R1 for proper operation,
replace if needed.
3. Excessive distribution line
leakage or blockage.
3.1 Check for leakage or blockage.