Drain Connections
A single drain connection is provided on the
bottom of the main enclosure. The tank drain line
discharges through a ball valve beneath the tank
into a small sump.
The 1½ inch pipe cap must be removed before the
tank or any spilled oil is drained from the enclosure.
(Fig. 34)
important note: The cabinet drain can be
permanently plumbed to a waste oil system
if desired, but a shut-off valve must be provided
at the bottom of the cabinet to maintain cabinet
sealing when the drain is not in use.
before start-up
Inspect your Carbon Shield
™
console
• Make sure components, electrical and
mechanical, are securely connected.
• Check wiring; ensure terminal screws are secure.
• The tank drain ball valve must be CLOSED
before oil is loaded into the tank. (Fig. 35)
• Ensure that the unit is properly grounded
through the grounding lug supplied inside the
cabinet. (Fig. 36)
• back off the inlet air pressure regulator (inside
the cabinet) to its minimum setting before open-
ing the air line to the oil mist unit. (Fig. 37)
NEW PHOTO TO COME
Fig. 36
operation
Fig. 37 Shown in ‘off ’ position
Fig. 38
Содержание Carbon Shield
Страница 1: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL ...
Страница 2: ......
Страница 4: ...2 www alemitecarbonshield com Fig 01 ...
Страница 5: ...Alemite Carbon Shield Service Guide 3 www alemitecarbonshield com Fig 02 ...
Страница 39: ...Alemite Carbon Shield Service Guide 37 www alemitecarbonshield com ...
Страница 53: ...Alemite Carbon Shield Service Guide 51 www alemitecarbonshield com Wiring Diagrams Relay Wiring Fig 92 Fig 92 ...
Страница 57: ...References Installed Arrangement Fig 95 Fig 95 www alemitecarbonshield com ...