www.alemitecarbonshield.com
ALEMITE CARbON SHIELD SERvICE SHEET | 17
Systems Connections
With the console secured, the air, oil, and electrical
systems can be connected.
Air system connections
Inlet air
The installation of a manual shut-off valve at the air
inlet point outside the cabinet is recommended.
The customer-supplied air line connects to a
flow diverting ball valve on the left side of the mist
console. This valve allows for the air supply to be
re-directed to the main or backup unit. This is not
a shut-off valve. (Fig. 25)
Note: Air delivered to this connection must be dry
and filtered instrument-quality and the pressure
regulated to 70-150 psi (4.92-10.55 kg/cm2).
Oil Inlet
(with optional auto-refill package)
The customer supplied oil inlet line connects
to the ¾ inch NPT at the inlet side of the oil filter
assembly. (Fig. 25) There is a ¼ inch ball valve in
the oil line inside the oil mist cabinet. Should the
system require maintenance, this manual shut-off
valve permits isolation from the refill pump
(separate from the oil mist system) without
locating and turning off the pump. Oil pressure
delivered to the inlet connection must not exceed
100 psi (7.03 kg/cm2).
To prevent contamination or clogging of the
piping, fittings or both.
Seal all air and oil connections with Loctite® 592 (Teflon).
Do not apply sealant to the first two (2) threads.
This equipment is designed to work in
Class I, Division 2, Groups B, C, and D,
Temperature Code T4 Hazardous Locations.
Always de-energize and ground this equipment. Read and
understand this manual before installation, operating, or
maintaining the equipment. Work on this equipment should
be done by qualified personnel. The use of unauthorized
parts or tampering by unqualified personnel may result in
dangerous conditions which may cause death, severe injury, or
equipment and property damage. Follow all safety instructions
contained herein.
Fig. 27
Fig. 28
Содержание Carbon Shield
Страница 1: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL ...
Страница 2: ......
Страница 4: ...2 www alemitecarbonshield com Fig 01 ...
Страница 5: ...Alemite Carbon Shield Service Guide 3 www alemitecarbonshield com Fig 02 ...
Страница 39: ...Alemite Carbon Shield Service Guide 37 www alemitecarbonshield com ...
Страница 53: ...Alemite Carbon Shield Service Guide 51 www alemitecarbonshield com Wiring Diagrams Relay Wiring Fig 92 Fig 92 ...
Страница 57: ...References Installed Arrangement Fig 95 Fig 95 www alemitecarbonshield com ...