Troubleshooting Chart | 41
WWW.ALEMITECARbONSHIELD.COM
troubleshooting chart
Problem
Possible cause
Possible solution
Low air temperature
1. Air Heater malfunction
1.1 Press the “Parameter values” button on
the main menu screen to display the air
temperature. Factory default is 100 °F
(37.8° C).
1.2 Ensure that the air supply pressure is
between 70 psi and 150 psi (4.92 and
10.55 kg/cm
2
), and the regulated air
pressure is between 32 psi and 40 psi
(2.25 and 2.81 kg/cm
2
).
1.3 Ensure that the mist pressure is above
10 in. H
2
O.*
*If this is the case, please see Low
Mist Pressure to continue the
troubleshooting.
1.4 Check the operation of control relay R0
and fuses F1 & F9. Replace as needed.
(Refer to Wiring Diagram)
1.5 If there is a 24 vdc signal from the PLC
to the coil of relay R0, and the relay is
not operating, fuse F1 may be open. If
there is no 24vdc to coil, fuse F9 may
be open. Replace as needed. (Refer to
Wiring Diagram)
1.6 Repairs to the Air Heater beyond this
point are out of the scope of this
manual. Please change over from
the main unit to the backup unit. Turn
off the power to the main unit and contact
Customer Service at 1-800-822-4579.
Содержание Carbon Shield
Страница 1: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL ...
Страница 2: ......
Страница 4: ...2 www alemitecarbonshield com Fig 01 ...
Страница 5: ...Alemite Carbon Shield Service Guide 3 www alemitecarbonshield com Fig 02 ...
Страница 39: ...Alemite Carbon Shield Service Guide 37 www alemitecarbonshield com ...
Страница 53: ...Alemite Carbon Shield Service Guide 51 www alemitecarbonshield com Wiring Diagrams Relay Wiring Fig 92 Fig 92 ...
Страница 57: ...References Installed Arrangement Fig 95 Fig 95 www alemitecarbonshield com ...