24 | alemite Carbon Shield Service Sheet
10. Select “Tank Size” in upper left corner.
Choose 3 gallon (11.4 L) tank (Fig 53).
10a. If the unit is equipped with the automatic refill
option, let the automatic refill system fill the
tank to 3 gallon (11.4 L) level. (Fig. 54)
10b. Note oil level as displayed on HMI and
compare this level to the site glass. Allow
several minutes for the oil level to settle.
11. If the oil level is within 5% of the displayed level,
the oil you are using is compatible with the
factory default level calibration and your system
requires no further calibration.
11a. Now you may elect to keep the 3 gallon
(11.4 L) capacity setting or change to a
5 gallon (18.9 L) capacity setting.
11b. If 5 gallon (18.9 L) tank is selected, let the
automatic refill complete the operation.
11c. Go to step 25 of this procedure.
12. If the oil level is not within 5% of the indicated
level, your level sensor needs to be calibrated.
13. Drain the tank below the zero mark on the
level gauge.
14. Note: Due to the size of the orifice in the sight
glass and depending on the oil viscosity and
temperature, the oil level in the sight glass will
take longer than the actual oil level inside the
tank to change. During the following procedure,
always stop the refill or drain the tank up to
about ¼ gallon of the intended mark and wait
for the level in the sight glass to stop changing.
This may take two to three minutes.
15. Select “Calibrate Oil Level” located in the upper
center of the System Setup screen (Fig 53).
16. Follow instructions on the Calibrate Oil Level
screen: (Fig 56)
a. Set tank size to 5 gallons (18.9 L) with
Auto Refill OFF.
b. Press the “OIL SOL” button below to start
oil fill.
c. Press “OIL SOL” button a second time
to stop oil fill.
d. Fill tank until oil is even with “zero”
on site glass.
e. Press “ZERO” button.
f. Fill tank to 5 Gallons on site glass.
g. Press “MAX FILL”.
Fig. 52
Fig. 53
Fig. 54
Содержание Carbon Shield
Страница 1: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL ...
Страница 2: ......
Страница 4: ...2 www alemitecarbonshield com Fig 01 ...
Страница 5: ...Alemite Carbon Shield Service Guide 3 www alemitecarbonshield com Fig 02 ...
Страница 39: ...Alemite Carbon Shield Service Guide 37 www alemitecarbonshield com ...
Страница 53: ...Alemite Carbon Shield Service Guide 51 www alemitecarbonshield com Wiring Diagrams Relay Wiring Fig 92 Fig 92 ...
Страница 57: ...References Installed Arrangement Fig 95 Fig 95 www alemitecarbonshield com ...