40 | alemite Carbon Shield Service Guide
WWW.ALEMITECARbONSHIELD.COM
troubleshooting chart
Problem
Possible cause
Possible solution
High mist pressure
1. Mist pressure set point
too high.
1.1 Press the “parameter values” button
on the main menu screen to display the
mist pressure value. Factory default is 20
inches H
2
O column or 50mbar.
1.2 Adjust mist pressure by pressing the
“Change Parameter” button on the main
menu, then the Air Flow Parameters,
then the + or – buttons on the “Flow
Parameters” screen adjust to the desired
mist pressure level.
2. Mist fitting blockage or
other distribution system
related issue.
2.1 High mist pressure may be the result
of blockage in mist fittings due to
accumulation of wax in the mist fittings
from paraffin based oils. Check the
alarm log for blockage alarm and time,
repair or replace fittings as needed.
2.2 Check for kinks in mist supply lines,
repair as needed. blockage alarm
will be logged and time stamped
in alarm log.
2.3 vent lines plugged or kinked, the CS
may indicate blockage alarm.
Transducer Regulator
out of range alarm in the
alarm log when there
is no high or low mist
pressure indicted in
the HMI
1. Transducer Regulator
malfunction.
3.1 Transducer Regulator malfunction is
very unlikely. The replacement of the
transducer regulator is out of the scope
of this manual. Please change over from
the main unit to the backup unit.
Turn off the power to the main unit
and contact Customer Service
at 1-800-822-4579.
Содержание Carbon Shield
Страница 1: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL ...
Страница 2: ......
Страница 4: ...2 www alemitecarbonshield com Fig 01 ...
Страница 5: ...Alemite Carbon Shield Service Guide 3 www alemitecarbonshield com Fig 02 ...
Страница 39: ...Alemite Carbon Shield Service Guide 37 www alemitecarbonshield com ...
Страница 53: ...Alemite Carbon Shield Service Guide 51 www alemitecarbonshield com Wiring Diagrams Relay Wiring Fig 92 Fig 92 ...
Страница 57: ...References Installed Arrangement Fig 95 Fig 95 www alemitecarbonshield com ...