www.alemitecarbonshield.com
14 | alemite Carbon Shield Service Sheet
bulk Oil Storage System
(Accessory)
The bulk oil storage system (Fig 17) operates
in conjunction with the auto-refill option to
continuously replenish oil in the reservoir. The
bulk oil tank is designed to be installed close
to a supply route for ease of maintenance and
installation. The 110 gallon (416 L) tank is sloped
to allow any water to drain away from the pump
suction. A single air operated oil pump is used to
transfer oil from bulk storage tank to the reservoir
of the main and the back up generators. A pressure
relief valve is provided to vent excess pressure
resulting from thermal oil expansion created
by daily ambient temperature variations. The
installer/customer is responsible for connecting
pipes between the bulk oil tank and the main console.
Oil Temperature
The PLC monitors oil temperature by means
of a thermocouple in the tank and maintains the
temperature by cycling the oil heater on and off.
The oil temperature is displayed in the HMI. The
analog thermometer also provides the operator
a readout of the oil temperature. (Fig. 18)
backup Generator
The backup generator is used when maintenance
or repairs are being done on the main unit. The
backup generator is mounted inside a NEMA 4X
enclosure of the same material as the enclosure of
the main generator and comes fully equipped with
its own air pressure controls, mist generating
head, oil reservoir, and instrumentation package.
A separate ON/OFF switch located inside the rear
cabinet and is used to power the control of the
backup unit. The heater for the backup unit will
be activated at all times, but controlled by a
thermostat to provide the desired oil temperature.
The back-up generator oil reservoir is filled
manually or from the bulk storage tank if the
optional auto refill feature is selected.
important note: The backup generator is intended
for intermittent use only. When operated for
purposes other than to perform maintenance
routine work on the main unit, it should be checked
at the beginning of every shift.
Fig. 17
Fig. 19
Fig. 18
Содержание Carbon Shield
Страница 1: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL ...
Страница 2: ......
Страница 4: ...2 www alemitecarbonshield com Fig 01 ...
Страница 5: ...Alemite Carbon Shield Service Guide 3 www alemitecarbonshield com Fig 02 ...
Страница 39: ...Alemite Carbon Shield Service Guide 37 www alemitecarbonshield com ...
Страница 53: ...Alemite Carbon Shield Service Guide 51 www alemitecarbonshield com Wiring Diagrams Relay Wiring Fig 92 Fig 92 ...
Страница 57: ...References Installed Arrangement Fig 95 Fig 95 www alemitecarbonshield com ...