B 120
Detailed description
of RS232 and RS485 commands
6/8
GB 00743 - Edition 04 - June 98
Alcatel Vacuum Technology France - User’s Manual ATH 1300 M/MT - ATH 1600 M/MT
SET
Syntax
Result
SPD
Syntax
Result
STA
Syntax
Result
Defines the internal operating parameters
#adr
SET
10,ccccc<CR>[<LF>] : pump working time (in hours)
#adr
SET
11,eeeee<CR>[<LF>] : electronic working time (in hours)
#adr
SET
13,ddddd<CR>[<LF>] : start relay (max 14459 s,
that is 240 mn59 s)
#adr
SET
14,pppp<CR>[<LF>] : time to venting (max 3559 s,
that is 59 mn 59 s)
#adr
SET
15,qqqq<CR>[<LF>] : venting time (max 3559 s,
that is 59 mn 59 s)
#adr
SET
30,jj<CR>[<LF>]
: speed threshold for relay (3 to 50%)
#adr
SET
31,kk<CR>[<LF>]
: control temperature (30 to 75°C)
#adr
SET
32,lll<CR>[<LF>]
: bearing threshold (0 to 100%)
#adr
SET
33,mmm<CR>[<LF>] : bearing current value (0 to 100%)
#adr,OK or ErrX
Returns the current speed
#adr
SPD
<CR>[<LF>]
#adr,nnnnn rpm
Returns the status of the internal dynamic parameters
#adr
STA
<CR> or STA<CR>
#adr,sss, rrrrr, vvv, www, xxx, yyy, zzz, aa, bbbbb, ccc, ddd,
ggggggggggggggggggggggggg<CR>
adr
: address
s1
: order
status
Bit
7
6
5
4
3
2
1
0
INH
LOCAL
STOP
(free)
REM
STDBY
START
0
OFF
OFF
OK
OFF
OFF
OFF
1
1
ON
ON
fault
ON
ON
ON
Содержание Adixen ATH 1300 M
Страница 1: ...ATH 1300 1600 M MT MAGLEV HYBRID TURBOMOLECULAR PUMPS User s Manual...
Страница 24: ......
Страница 26: ......
Страница 32: ......
Страница 44: ......
Страница 50: ......
Страница 62: ......
Страница 64: ......
Страница 68: ......
Страница 70: ......
Страница 82: ......
Страница 88: ......
Страница 96: ......
Страница 98: ......
Страница 112: ......
Страница 114: ......
Страница 116: ......
Страница 121: ...G 100 1 1 GB 02326 Edition 01 January 04 Alcatel Vacuum Technology France User s Manual ATH 1300 M MT ATH 1600 M MT...
Страница 122: ......