79
L1: Total length of Ø25.4mm liquid pipe (m);
L2: Total length of Ø22.22mm liquid pipe (m);
L3: Total length of Ø19.05mm liquid pipe (m);
L4: Total length of Ø15.88mm liquid pipe (m);
L5: Total length of Ø12.7mm liquid pipe (m);
L6: Total length of Ø9.52mm liquid pipe (m);
Total refrigerant volume charging on site during installation=W2+W3
W: Total refrigerant volume charging on site for maintenance.
Important notes
Separate the refrigerant system when exceeding values in the table below in
terms of filling quantity of refrigerant pipe.
Outdoor unit
Additional sealing-in quantity (kg)
8P~24P
50
26P~48P
100
50P~72P
150
As R410A refrigerant is adopted for the unit, the following matters will be noted:
• Use special tools of different refrigerants to avoid mixture with different kinds of oil. Especially for instrument
collector and filling hose, never share tools with other refrigerants (R22, R407C, etc.).
• Mark different colors on refrigerant tanks to indicate the refrigerant types (pink for R410A) and ensure there is
no error.
• Never use charging cylinder. Refrigerant composition may be changed when R410A is transferred to the
cylinder.
• When charging the refrigerant, make sure to take it out of refrigerant tank in liquid form.
Refrigerant record form
Model
W1:
Refrigerant
charging
volume to
outdoor
unit at
factory
W2:
Refrigerant
charging
volume to
outdoor unit
on site
W3: Refrigerant charging volume
to liquid pipe base on different
piping length calculation
Total
refrigerant
volume
charging on
site during
installation
W: Total
refrigerant
volume
charging
on site for
maintenance
Liquid
pipe
diameter
(mm)
Additional refrigerant
amount
(kg)
AWAU-YDV250-H13
9.7kg
0kg
Ø9.52
0.054kg/m×__m=__kg
W2+W3=
___kg
W1+W2+
W3=___kg
AWAU-YDV280-H13
9.7kg
0kg
Ø12.7
0.11kg/m×__m=__kg
AWAU-YDV335-H13
(DROP ONLY)
9.7kg
0kg
Ø15.88
0.17kg/m×__m=__kg
AWAU-YDV400-H13
10kg
1kg
Ø19.05
0.25kg/m×__m=__kg
AWAU-YDV450-H13
10kg
3kg
Ø22.22
0.35kg/m×__m=__kg
AWAU-YDV504-H13
10kg
7.5kg
Ø25.4
0.45kg/m×__m=__kg
AWAU-YDV560-H13
10kg
7.5kg
W3=___kg
AWAU-YDV615-H13
(DROP ONLY)
10kg
10kg
AWAU-YDV680-H13
10kg
10kg
Содержание AWAU-YDV1010-H13
Страница 1: ...SYJS 03 2017 REV A Edition 2017 03 Service Manual Flow Logic III...
Страница 56: ...54 7 Operation range...
Страница 102: ...100 Power module driver board 0151800090B and 0151800090...
Страница 103: ...101 Filter board MHW505A012...
Страница 187: ...Airwell reserves the right to make change without any notice...