60
Warning
•
I
f refrigerant leaks during operation, please take measures for ventilation and aeration.
the refrigerant will cause poisonous gas as meeting fire.
•
A
fter installation, please confirm whether or not there is refrigerant leakage.
If the refrigerant leaks indoors, it will generate poisonous gas after meeting fan heater, furnace, oven
and other fire sources.
•
I
f the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
•
T
his appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
•
C
hildren should be supervised to ensure that they do not play with the appliance.
•
T
his appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made
by children without supervision.
•
T
he appliances are not intended to be operated by means of an external timer or separate remote-
control system.
•
K
eep the appliance and its cord out of reach of children less than 8 years.
•
O
perating valve (both gas side and liquid side) cannot be open before completion of refrigerant pipe
works, airtight test and vacuum pumping and other steps.
•
R
apid leakage of the refrigerant will cause cold injury or other injury.
•
D
rainage pipe cannot be connected directly to drainage tank which produces sulfur gases and other
harmful gases.
•
O
therwise, the poisonous gas may enter the indoor. Besides, it may corrode indoor units and cause
fault of indoor units or leakage of the refrigerant.
•
D
uring installation or relocation of air conditioner, the air other than the specified refrigerant (R410A)
cannot be mixed into refrigeration cycle system.
•
I
f the air is mixed into the system, it will generate abnormal high pressure in refrigeration cycle system,
further inducing breakage, injury, etc.
Содержание AWAU-YDV1010-H13
Страница 1: ...SYJS 03 2017 REV A Edition 2017 03 Service Manual Flow Logic III...
Страница 56: ...54 7 Operation range...
Страница 102: ...100 Power module driver board 0151800090B and 0151800090...
Страница 103: ...101 Filter board MHW505A012...
Страница 187: ...Airwell reserves the right to make change without any notice...