Page 71
hELi MODEL TyPE
1) Press the Navigation Pad
56
to highlight HOLD>INH, then press the
INC+/M1 or DEC-/M2 keys to change the INH/ACT setting to ACT.
HOLD setting range is INH/ACT. The default setting is INH. When
Activated, the Throttle Hold function will be Active for that Flight Mode.
When you Activate the Throttle Hold function, you will not be able to program the Throttle Curve Function. In addition,
when the Throttle Hold function is Activated, the throttle control stick will control Pitch only and the Throttle trim switch
will be Inhibited.
RATE setting range for each Point is -150% to 150%.
3) Press the Navigation Pad
6
to highlight RATE>.
4) Press the INC+/M1 or DEC-/M2 keys to set the desired Rate percentage
value for the Point you chose previously, then repeat the previous
procedures to change the desired remaining Point and Rate percentage
values.
Activating the Throttle Hold Function and Changing the Rate Percentage Value
WARNING
Keep in mind that it's possible to set the Throttle Hold percentage value lower than the throttle End Point
Adjustment percentage value. For example, with the throttle End Point Adjustment percentage value set to -100% and the
Throttle Hold percentage value set to -150% the servo will move -150% when the Throttle Hold is Activated. We strongly
recommend that you set the Throttle Hold Rate percentage value no higher than your throttle End Point Adjustment percentage
values unless specifically necessary for your particular setup. This will prevent any chance of overdriving your control linkage.
1) Press the Navigation Pad
6
to highlight POINT>1.
2) Press the INC+/M1 or DEC-/M2 keys to choose which Point you would
like to set a Rate percentage value for.
POINT setting range is 1 through 5. Point 1 is at the low end of the Throttle Curve and Point 5 is at the high end of the Throttle
Curve. Point 3 is a the center of the Throttle Curve.
In the default configuration the Throttle Curve is Linear. For example, when you move the throttle control stick from 0%
to 100%, the throttle servo will travel from 0% to 100%, too. As long as the line on the graph remains straight, the Throttle
Curve will be Linear. When a Point Rate percentage value is changed, the line on the graph curves (displaying the Throttle Curve)
and throttle servo travel will vary in relation to throttle control stick movement.
100%
The tables below describe the default Point and Rate values.
1
2
-100%
-50%
POINT
DEFAULT RATE
3
4
0%
50%
POINT
DEFAULT RATE
5
POINT
DEFAULT RATE
Changing the Throttle Curve Point Values and the Rate Percentage Values, Continued....
HELI MODEL
TYPE
Содержание SD-6G