Page 43
aERO MODEL TyPE
Programming F-MODE
Transmitter F-MODE
Transmitter F-MODE refers to the Flight Mode that the transmitter is currently operating in. Programming F-MODE refers
to the Flight Mode that you would like to change the programming for.
18.DUaL EL (DUaL ELEvaTOR MiXing EnD POinT aDjUSTMEnT), cOnTinUED....
IMPORTANT
To be able to access the DUAL EL menu and program the Dual Elevator End Point Adjustment function, your aircraft
must feature two separate elevator servos and you must choose the TAIL>2xEL Model Type selection option in the TYPE menu.
Choosing the Flight Mode - Common or Separate
1) From the Display screen, press the ENTER key to display the Programming
Menus.
2) Press the Navigation Pad
56
to highlight DUAL EL, then press the
ENTER key to display the DUAL EL menu. The cursor will default to
LE-D>80%.
3) Press the Navigation Pad
5
to move the cursor to F-MODE>COMMON.
4) Press the INC+/M1 or DEC-/M2 keys to choose either SEPARATE or
COMMON.
5) If you choose SEPARATE, press the F-MODE key to choose the F-MODE
number you would like to program the Dual Elevator Mixing End Point
Adjustment function for. Choose from FN, F1 or F2.
Changing Dual Elevator Mixing End Point Adjustment Percentage Values
Both the Up and Down, and the Right and Left elevator percentage values can be changed separately. Prior to changing the
Dual Elevator Mixing End Point Adjustment percentage values, you should adjust the elevator End Point Adjustment percentage
values in the EPA menu to achieve the desired maximum amount of control deflection in both directions. You can then lower the
required Dual Elevator Mixing End Point Adjustment percentage values to equalize the control deflection of both elevator halves
in both directions.
1) Press the Navigation Pad
56
to highlight the desired elevator servo
and direction of travel you would like to change the Dual Elevator Mixing
End Point Adjustment percentage value for. For example, if the Left
elevator half moves Up more than the Right elevator half moves Up,
you would decrease the LE-U>80% (Left Elevator-Up) percentage value.
2) Press the INC+/M1 or DEC-/M2 keys to set the desired Dual Elevator
Mixing End Point Adjustment percentage value.
DUAL EL setting range is 100% to 0%. The default setting is 80%. Decreasing the Dual Elevator Mixing End Point Adjustment
percentage value will decrease the movement for that specific elevator half and direction of travel.