Expresso Tie Stall
20 © 2012 Agricultural Instruments Corporation
(AIC) 608.526.6882
Settings
Range
Increments
Factory
Settings
Effects of Adjustment
Page 2
Retract Delay
0 to 10
seconds
.2 seconds
1.6 second
This delay allows for soft take
-
off. The
EXPRESSO control shuts the vacuum off
the claw and then activates the retraction
cylinder in the time this delay is set.
Pull Time
0 to 20
seconds
.5 seconds
10 seconds
If driving an electric motor, how long
power is to the motor.
Re
-
Pull Time
0 to 20
seconds
.5 seconds
2.8 Seconds
After the Pull Time expires, power is
again applied to the motor for the desired
amount of time.
Sweep Delay
0 to 20
seconds
.5 seconds
0 Seconds
Time from detach to milk sweep start.
Sweep On
-
Time
0 to 5
seconds
.2 seconds
1 seconds
How long sweep occurs for
Pulsation Rate
45
-
80 ppm
1
60ppm
Set
-
up for the number of pulsation cycles
per minute
Front Ratio
50/50 to
70/30
1
65/35
Set
-
up front pulsation milk/rest ratio
Rear Ratio
50/50 to
70/30
1
65/35
Set
-
up rear pulsation milk/rest ratio.
Detacher Control Set Up