Expresso Tie Stall
19 © 2012 Agricultural Instruments Corporation
(AIC) 608.526.6882
Setting
Range
Increments
Factory
Settings
Effects of Adjustment
Page 1
Language
N/A
Multiple
English
Choose Language Displayed
ID Enable
Yes/No
N/A
No
EXPRESSO Units will ask for an ID
number when starting milking
Units of Measure
LB/F or Kg/C
LB/F
Change from Imperial to Metric
Take Off Flow Rate
.2 to 6 LB/Min
.09 to 1.82 Kg/
Min
Varies
1.2 LB/Min.
Increase to milk cows wetter decrease to
milk cows drier
Take Off Delay
0 to 60
seconds
1 second
8 seconds
Increase to milk cows drier, decrease to
milk cows wetter.
Max Milking Time
0 to 20 minutes
30 seconds
0 seconds
Unit will detach after the maximum time
has expired, except when a continue as
occurred.
Conductivity Delay
0 to 3.9 LB
0 to 1.76 Kg
.1 LB
.4 Kg
3.5 LB
1.6 Kg
Increase to make less sensitive,
decrease to make more sensitive
Milk Letdown Delay
60 to 210
seconds
30 seconds
90 seconds
Increase for longer delay. Allows to
ignore low flow rates at the beginning of
milking.
Vacuum On Delay
0 to 10
seconds
.2 seconds
2 second
This setting is the delay from when the
attach switch is pressed and vacuum is
applied to the milking unit. It allows time
to get the milking unit into the milking
position before vacuum is applied.
Detacher Control Set Up