Programming Command Reference
5
N9360A Multi UE Tester W-CDMA Programming Manual
5-21
bit 5 (32): For testing RFCH6
The choices for each bit are
1
for Run and
0
for — (skip). At
preset, this is set to
63
.
This query command returns the setting of Inner Loop Power
test with integer. The meaning of the return value is same as
that of the command parameter.
MAX TX Power
CONFigure:SEQuence:TPOWer <int>
CONFigure:SEQuence:TPOWer?
This command sets whether or not to include MAX TX Power
test in the test sequence.
<int>
is a sum of the values of all the
6 bits as follows.
bit 0 (1): For testing RFCH1
bit 1 (2): For testing RFCH2
bit 2 (4): For testing RFCH3
bit 3 (8): For testing RFCH4
bit 4 (16): For testing RFCH5
bit 5 (32): For testing RFCH6
The choices for each bit are
1
for Run and
0
for — (skip). At
preset, this is set to
63
.
This query command returns the setting of MAX TX Power test
with integer. The meaning of the return value is same as that of
the command parameter.
Frequency Error
CONFigure:SEQuence:FREQuency <int>
CONFigure:SEQuence:FREQuency?
This command sets whether or not to include Frequency Error
tests in the test sequence.
<int>
is a sum of the values of all the
6 bits as follows.
bit 0 (1): For testing RFCH1
bit 1 (2): For testing RFCH2
Содержание N9360A
Страница 1: ...Agilent Technologies Agilent N9360A Multi UE Tester W CDMA Programming Manual...
Страница 4: ...1 4 N9360A Multi UE Tester W CDMA Programming Manual 1 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 8: ...8 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 12: ...6 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 16: ...1 4 N9360A Multi UE Tester W CDMA Programming Manual 1 Legal Information THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 180: ...8 20 N9360A Multi UE Tester W CDMA Programming Manual 8 Syntax Diagrams THIS PAGE IS INTENTIONALLY LEFT BLANK...