This command specifies the Band in order to set each BS Level
on each band. The parameter is
1
or
6
. At preset, this is set to
1
.
BS Level
CONFigure:SEQuence:AMPLitude <real>
CONFigure:SEQuence:AMPLitude?
This command specifies the amplitude (BS Level) in each band
set by the
command described above. The allowable range
is from
-110.0
to
-20.0
(dBm) in
0.1
steps. At preset, this is
set to
-65.7
(dBm).
Measurement BS Level
CONFigure:SEQuence:MEASurementbslevel <real>
CONFigure:SEQuence:MEASurementbslevel?
This command specifies the amplitude (BS Level) for
MAX TX
Power
,
Inner Loop Power
,
EVM
and
Origin Offset
measurement in each
band set by the
command described above. The allowable
range is from
-110.0
to
-20.0
(dBm) in
0.1
steps. At preset,
this is set to
-93.0
(dBm).
Openloop BS Level (Open Loop TX Power BS Level)
CONFigure:SEQuence:OLPbslevel <real>
CONFigure:SEQuence:OLPbslevel?
This command specifies the amplitude (BS Level) for
measurement in each band set by the
command described
on
. The allowable range is from
-110.0
to
-20.0
(dBm)
in
0.1
steps. At preset, this is set to
-65.7
(dBm).
BER BS Level
CONFigure:SEQuence:BERbslevel <real>
CONFigure:SEQuence:BERbslevel?
Содержание N9360A
Страница 1: ...Agilent Technologies Agilent N9360A Multi UE Tester W CDMA Programming Manual...
Страница 4: ...1 4 N9360A Multi UE Tester W CDMA Programming Manual 1 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 8: ...8 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 12: ...6 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 16: ...1 4 N9360A Multi UE Tester W CDMA Programming Manual 1 Legal Information THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 180: ...8 20 N9360A Multi UE Tester W CDMA Programming Manual 8 Syntax Diagrams THIS PAGE IS INTENTIONALLY LEFT BLANK...