![Agilent Technologies 4284A Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/agilent-technologies/4284a/4284a_operation-manual_2867874062.webp)
Measurement
Function
Description
The
4284A
measures
t
w
o
comp onen
ts
of
the
complex
imp edance
(parameters)
at
the
same
time
in
a
measuremen
t
cycle.
The
measuremen
t
parameters
are
listed
as
follows.
Primary
P
arameters
j Z j
(absolute
v
alue
of
imp edance)
j Yj
(absolute
v
alue
of
admittance)
L
(inductance)
C
(capacitance)
R
(resistance)
G
(conductance)
Secondary
P
arameters
D
(dissipation
factor)
Q
(qualit
y
factor)
R
s
(ESR
(equiv
alen
t
series
resistance))
R
p
(equiv
alen
t
parallel
resistance)
X
(reactance)
B
(susceptance)
(phase
angle)
The
primary
parameter
measuremen
t
result
is
lo
cated
on
the
upp er
line
as
t
w
o
large
c
haracter
lines
on
this
page,
and
the
secondary
parameter
measuremen
t
result
is
lo
cated
on
the
low
er
line
as
t
w
o
large
c
haracter
lines
on
this
page.
The
com
binations
of
primary
and
secondary
parameters,
including
the
equiv
alen
t
parallel
and
serial
com
binations,
are
listed
in
T
able
3-1.
3-4
DISPLA
Y
F
ORMA
T
Menu
Содержание 4284A
Страница 12: ......
Страница 37: ...Figure 1 1 Power Cable Supplied Installation and Set Up Guide 1 3 ...
Страница 54: ...Figure 2 5 Display Pages 1 3 2 12 Overview ...
Страница 55: ...Figure 2 5 Display Pages 2 3 Overview 2 13 ...
Страница 56: ...Figure 2 5 Display Pages 3 3 2 14 Overview ...
Страница 58: ...Figure 2 7 Softkey Selection Example 2 16 Overview ...
Страница 60: ...Figure 3 1 Available Fields on the MEAS DISPLAY Page 3 2 DISPLAY FORMAT Menu ...
Страница 61: ...Figure 3 2 Available Softkeys on the MEAS DISPLAY Page DISPLAY FORMAT Menu 3 3 ...
Страница 66: ...Figure 3 4 Effective Measuring Range Oscillator Level 2V or 20 mA 3 8 DISPLAY FORMAT Menu ...
Страница 91: ...Figure 3 15 Available Fields on the LIST SWEEP DISPLAY Page DISPLAY FORMAT Menu 3 33 ...
Страница 96: ......
Страница 99: ...Figure 4 2 Available Softkeys on the MEAS SETUP Page MEAS SETUP Menu 4 3 ...
Страница 104: ...Figure 4 5 Available Operating Area for the ALC Function 4 8 MEAS SETUP Menu ...
Страница 113: ...4 Press NNNNNNNNNNN YES to reset the 4284A MEAS SETUP Menu 4 17 ...
Страница 115: ...Figure 4 8 Available Fields on the CORRECTION Page MEAS SETUP Menu 4 19 ...
Страница 116: ...Figure 4 9 Available Softkeys on the CORRECTION Page 4 20 MEAS SETUP Menu ...
Страница 131: ...Figure 4 15 Available Fields on the LIMIT TABLE SETUP Page MEAS SETUP Menu 4 35 ...
Страница 145: ...Figure 4 21 Available Fields on the LIST SWEEP SETUP Page MEAS SETUP Menu 4 49 ...
Страница 152: ......
Страница 158: ...Figure 5 4 Available Fields on the SYSTEM CONFIG Page 5 6 Catalog System Configuration ...
Страница 182: ...Figure 6 12 Measurement Contacts for Test Leads Extension 6 14 Measurement Procedure and Examples ...
Страница 228: ...Figure 7 19 Standard Event Status Register 7 28 Remote Control ...
Страница 240: ......
Страница 361: ...Caution The memory card should be removed before packing the 4284A General Information 9 29 ...
Страница 362: ......
Страница 432: ......
Страница 436: ......
Страница 440: ......
Страница 450: ...Figure G 8 Short Circuit Recovery Delay Times 3 G 10 Transient States Caused by Measurement Condition Changes ...
Страница 460: ......