![Agilent Technologies 4284A Скачать руководство пользователя страница 412](http://html.mh-extra.com/html/agilent-technologies/4284a/4284a_operation-manual_2867874412.webp)
Sample
Program
to
Detect
the
Error
When
y
ou
write
an
GPIB
con
trol
program
for
the
4284A,
the
follo wing
sample
program
is
a
useful
debugging
to
ol
(using
the
4284A
status
b
ytes
and
the
SYST:ERRor?
query)
for
detecting
the
errors.
100
OUTPUT
717;"*ESE
60"
!
Event
Status
Resister
enable
110
!
(error
bits
enable)
120
OUTPUT
717;"*SRE
32"
!
Status
Byte
Resister
enable
130
!
(Event
Status
Summary
bit
enable)
140
ON
INTR
7,2
CALL
Errors
150
ENABLE
INTR
7;2
.
.
.
500
SUB
Errors
510
DIM
Err$[50]
520
Sp=SPOLL(717)
530
IF
BIT(Sp,5)
THEN
540
OUTPUT
717;"*ESR?"
!
Clear
the
Event
Status
Resister
550
ENTER
717;Esr
560
"Event
Status
Resister
=";Esr
570
LOOP
580
OUTPUT
717;"SYST:ERR?"!
Error
No.
&
message
query
590
ENTER
717;Err$
600
EXIT
IF
VAL(Err$)=0
!
Exit
if
no
error
610
Err$
620
END
LOOP
630
END
IF
640
ENABLE
INTR
7;2
650
SUBEND
B-2
Error
and
W
arning
Messages
Содержание 4284A
Страница 12: ......
Страница 37: ...Figure 1 1 Power Cable Supplied Installation and Set Up Guide 1 3 ...
Страница 54: ...Figure 2 5 Display Pages 1 3 2 12 Overview ...
Страница 55: ...Figure 2 5 Display Pages 2 3 Overview 2 13 ...
Страница 56: ...Figure 2 5 Display Pages 3 3 2 14 Overview ...
Страница 58: ...Figure 2 7 Softkey Selection Example 2 16 Overview ...
Страница 60: ...Figure 3 1 Available Fields on the MEAS DISPLAY Page 3 2 DISPLAY FORMAT Menu ...
Страница 61: ...Figure 3 2 Available Softkeys on the MEAS DISPLAY Page DISPLAY FORMAT Menu 3 3 ...
Страница 66: ...Figure 3 4 Effective Measuring Range Oscillator Level 2V or 20 mA 3 8 DISPLAY FORMAT Menu ...
Страница 91: ...Figure 3 15 Available Fields on the LIST SWEEP DISPLAY Page DISPLAY FORMAT Menu 3 33 ...
Страница 96: ......
Страница 99: ...Figure 4 2 Available Softkeys on the MEAS SETUP Page MEAS SETUP Menu 4 3 ...
Страница 104: ...Figure 4 5 Available Operating Area for the ALC Function 4 8 MEAS SETUP Menu ...
Страница 113: ...4 Press NNNNNNNNNNN YES to reset the 4284A MEAS SETUP Menu 4 17 ...
Страница 115: ...Figure 4 8 Available Fields on the CORRECTION Page MEAS SETUP Menu 4 19 ...
Страница 116: ...Figure 4 9 Available Softkeys on the CORRECTION Page 4 20 MEAS SETUP Menu ...
Страница 131: ...Figure 4 15 Available Fields on the LIMIT TABLE SETUP Page MEAS SETUP Menu 4 35 ...
Страница 145: ...Figure 4 21 Available Fields on the LIST SWEEP SETUP Page MEAS SETUP Menu 4 49 ...
Страница 152: ......
Страница 158: ...Figure 5 4 Available Fields on the SYSTEM CONFIG Page 5 6 Catalog System Configuration ...
Страница 182: ...Figure 6 12 Measurement Contacts for Test Leads Extension 6 14 Measurement Procedure and Examples ...
Страница 228: ...Figure 7 19 Standard Event Status Register 7 28 Remote Control ...
Страница 240: ......
Страница 361: ...Caution The memory card should be removed before packing the 4284A General Information 9 29 ...
Страница 362: ......
Страница 432: ......
Страница 436: ......
Страница 440: ......
Страница 450: ...Figure G 8 Short Circuit Recovery Delay Times 3 G 10 Transient States Caused by Measurement Condition Changes ...
Страница 460: ......