30.
Connect
the
2
m
T
est
Leads
(16048D)
to
the
UNKNOWN
terminals.
31.
Press
the
4
MEAS
SETUP
5
MENU
k
ey
and
the
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
CORRECTION
softkey
to
display
the
CORRECTION
page.
32.
Set
the
CABLE
to
2
m.
33.
Store
the
OPEN
CORRECTION
data
and
the
SHOR
T
CORRECTION
data
referring
to
Step
4
through
9.
In
this
pro cedure
the
OPEN
termination
and
the
SHOR
T
termination
should
b e
connected
to
the
2
m
T
est
Leads
(16048D).
34.
Set
the
4284A
to
the
Manual
T
rigger
mo
de.
35.
Set
the
measuremen
t
function
to
Cp-D.
36.
Connect
the
1000
pF
standard
to
the
2
m
T
est
Leads
(16048D).
37.
P
erform
Steps
38
through
39
for
all
the
test
frequencies
listed
in
T
able
10-10.
38.
Press
the
4
TRIGGER
5
k
ey
.
39.
Conrm
that
the
4284A's
reading
is
within
the
test
limits
in
T
able
10-10.
40.
Connect
the
4
m
T
est
Leads
(16048E)
to
the
UNKNOWNterminals.
41.
Press
the
4
MEAS
SETUP
5
MENU
k
ey
and
the
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
CORRECTION
softkey
to
display
the
CORRECTION
page.
42.
Set
the
CABLE
to
4
m.
43.
Store
the
OPEN
CORRECTION
data
and
the
SHOR
T
CORRECTION
data
referring
to
steps
4
through
9.
In
this
pro cedure
the
OPEN
termination
and
the
SHOR
T
termination
should
b e
connected
to
the
4
m
T
est
Leads
(16048E).
44.
Set
the
4284A
to
the
Manual
T
rigger
mo
de.
45.
Set
the
measuremen
t
function
to
Cp-D.
46.
Connect
the
1000
pF
standard
to
the
4
m
T
est
Leads
(16048E).
47.
P
erform
Steps
48
through
49
for
all
the
test
frequencies
listed
in
T
able
10-10.
48.
Press
the
4
TRIGGER
5
k
ey
.
49.
Conrm
that
the
4284A's
reading
is
within
the
test
limits
listed
in
T
able
10-10.
10-18
P
erformance
T
ests
Содержание 4284A
Страница 12: ......
Страница 37: ...Figure 1 1 Power Cable Supplied Installation and Set Up Guide 1 3 ...
Страница 54: ...Figure 2 5 Display Pages 1 3 2 12 Overview ...
Страница 55: ...Figure 2 5 Display Pages 2 3 Overview 2 13 ...
Страница 56: ...Figure 2 5 Display Pages 3 3 2 14 Overview ...
Страница 58: ...Figure 2 7 Softkey Selection Example 2 16 Overview ...
Страница 60: ...Figure 3 1 Available Fields on the MEAS DISPLAY Page 3 2 DISPLAY FORMAT Menu ...
Страница 61: ...Figure 3 2 Available Softkeys on the MEAS DISPLAY Page DISPLAY FORMAT Menu 3 3 ...
Страница 66: ...Figure 3 4 Effective Measuring Range Oscillator Level 2V or 20 mA 3 8 DISPLAY FORMAT Menu ...
Страница 91: ...Figure 3 15 Available Fields on the LIST SWEEP DISPLAY Page DISPLAY FORMAT Menu 3 33 ...
Страница 96: ......
Страница 99: ...Figure 4 2 Available Softkeys on the MEAS SETUP Page MEAS SETUP Menu 4 3 ...
Страница 104: ...Figure 4 5 Available Operating Area for the ALC Function 4 8 MEAS SETUP Menu ...
Страница 113: ...4 Press NNNNNNNNNNN YES to reset the 4284A MEAS SETUP Menu 4 17 ...
Страница 115: ...Figure 4 8 Available Fields on the CORRECTION Page MEAS SETUP Menu 4 19 ...
Страница 116: ...Figure 4 9 Available Softkeys on the CORRECTION Page 4 20 MEAS SETUP Menu ...
Страница 131: ...Figure 4 15 Available Fields on the LIMIT TABLE SETUP Page MEAS SETUP Menu 4 35 ...
Страница 145: ...Figure 4 21 Available Fields on the LIST SWEEP SETUP Page MEAS SETUP Menu 4 49 ...
Страница 152: ......
Страница 158: ...Figure 5 4 Available Fields on the SYSTEM CONFIG Page 5 6 Catalog System Configuration ...
Страница 182: ...Figure 6 12 Measurement Contacts for Test Leads Extension 6 14 Measurement Procedure and Examples ...
Страница 228: ...Figure 7 19 Standard Event Status Register 7 28 Remote Control ...
Страница 240: ......
Страница 361: ...Caution The memory card should be removed before packing the 4284A General Information 9 29 ...
Страница 362: ......
Страница 432: ......
Страница 436: ......
Страница 440: ......
Страница 450: ...Figure G 8 Short Circuit Recovery Delay Times 3 G 10 Transient States Caused by Measurement Condition Changes ...
Страница 460: ......