THE AGA GATEMASTER 900 AUTOMATIC SWING GATE SYSTEM 

 

Product Description and Applications 

This system is for residential or light commercial automation of a swinging gate. 

 
Technical Specifications: 

Motor: 24V DC motor with mechanical release  
Gear type: worm gear 
Max absorbed power: 144W  
Peak thrust: 3500N  
Nominal thrust: 3000N 
Duty cycle: 20% 
Stroke length: 12 inches 
Power supply: 110V AC converted to 24V DC with built in transformer 
Nominal input power: 2A 
Maximum operating current: 5.5A for maximum 10 seconds 
Maximum gate weight: 500 lbs 
Maximum gate length: 14 feet  
Control Panel Voltage: 24V AC, available for 24V DC backup battery 
Suitable for single or dual swing gate opener 
Radio Controls: 433 MHz customized rolling code 
Support remote control: Can memorize 120 transmitters at most 
Actuators: 24V DC Actuator x2 
 
 
 

This diagram shows a typical installation including some optional accessories: 

 
 

 

Содержание GATEMASTER 900 HD

Страница 1: ...1 AGA GATEMASTER 900 HD AGA GATEMASTER 900 HD Installation Manual...

Страница 2: ...d with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions Failure to follow installati...

Страница 3: ...ny components unless shown in this manual Do not try to manually open or close the gate without pulling up the release lever If there is a failure that cannot be solved and is not mentioned in this ma...

Страница 4: ...length 12 inches Power supply 110V AC converted to 24V DC with built in transformer Nominal input power 2A Maximum operating current 5 5A for maximum 10 seconds Maximum gate weight 500 lbs Maximum gat...

Страница 5: ...to shrink and expand The hinges cannot be mounted in the center of a column The angle will be too wide If you mount on a column make sure that the gate hinges are within 4 of the back of the column If...

Страница 6: ...6...

Страница 7: ...gate open NOTE The operator shaft will be fully extended when the gate is closed and fully retracted when the gate is open Note that there is not a limit setting on the control board Simply manually...

Страница 8: ...release lever then extend the arm all the way out The arm will be in this completely extended position when the gate is closed Determine where you will mount the operator It is better to be near the...

Страница 9: ...ng points Making sure the bracket is level drill four 3 8 holes through the hinge post and fasten the bracket with nuts and washers Note Drilling and bolting all the way through the post is the strong...

Страница 10: ...will be in this completely retracted position when the gate is closed The arm will be completely extended when the gate is open Determine where the operator will be mounted It is better to place it n...

Страница 11: ...is the strongest method but if it is not possible to drill through the post you could use quarter inch self tapping screws If that is necessary regularly check that the screws are tight Drill and bol...

Страница 12: ...amp hour batteries must be wired IN SERIES to provide 24V DC See wiring diagram Important Connect the charge controller to the batteries FIRST and then connect the solar panel to the charge controlle...

Страница 13: ...up Battery backup is not required In the event of a power failure there is a manual release lever on the top of each operator arm which allows the gates to be opened manually Turn the key and lift the...

Страница 14: ...onal accessory wires Connect the Operator Arms Cables to the Control Board Bi Parting Double Gate Connect cable from the Primary operator arm on the near side of the driveway Connect the Black wire to...

Страница 15: ...E Have the keypad in hand at the gate control box when programming Do not mount keypad on gooseneck mounting post yet Step 1 Program the keypad to the gate operator Enter 0000 to enter programming mod...

Страница 16: ...may be mounted on brackets mounted to the gate posts or on small metal or wood stakes on each side of the driveway For a double gate photo eyes are mounted to shoot the beam directly across the drive...

Страница 17: ...s triggered to open Dig a shallow trench and bury the exit sensor It is not necessary to use a PVC conduit but it is a good idea in order to protect it and to make it easier to replace Wiring Instruct...

Страница 18: ...its own radio receiver and two remotes come with the system In some cases you might want to add another receiver for example if you want to use a different wireless keypad such as the Liftmaster KPW5...

Страница 19: ...19...

Страница 20: ...output is used for connecting photo eye sensor Continuous output current 200mA 8 24V battery output is used for connecting the backup battery 9 24V battery output is used for connecting the backup bat...

Страница 21: ...it means the system is normal Basic Function Setting Method To begin programming press and hold the FUN function button until the digital display shows P0 Press INC or DEC to increase or decrease the...

Страница 22: ...t is 0 seconds P8 Sets the close delay time for the gate to close when utilizing a magnetic lock This staggers the gates so that they don t close at the same time Can be set from 0 to 10 seconds 1 mea...

Страница 23: ...t this to 1 for a Single gate or 2 for Double gates NOTE Keypad should be set to channel 2 for a double gate Pd Safety photo beam setting Specifies which type of contact the safety photo beam is using...