21
19.
Motor1- terminal is used for connecting the secondary operator arm (actuator) (-)
20.
terminal is used for connecting the secondary operator arm (actuator) (+)
21.
terminal is used for connecting the primary operator arm or
for use with a single gate; positive (+)
22.
Motor2 - terminal is used for connecting the primary operator arm or
for use with a single gate; negative (-)
23.
AC24V input is used for connecting the transformer
24.
AC24V input is used for connecting the transformer
25.
Digital display is used for showing the setting value
26.
INC+ is used to increase the digital setting value
27.
FUN is used to store the settings (function)
28.
DEC- is used to decrease the digital setting value
29.
Learn Button is used for programming the remote transmitters and wireless keypad
30.
10-amp board fuse
Control Board Settings
Note: After power on, the digital display will self-check from 00-99 and
sound the buzzer. If the blue LED indicator is on, and the buzzer stops
buzzing, it means the system is normal.
Basic Function Setting Method:
To begin programming, press and hold the FUN (function) button until the
digital display shows P0.
Press INC+ or DEC- to increase or decrease the numerical value.
After you select the value you want, press FUN to store the setting.
One buzz indicates the setting has been stored.
Programming can be terminated at any time by pressing the LEARN button.
After storing the setting, the digital display will stay on the same setting
number. To go to the next setting number, press INC+ or DEC- and
confirm with FUN. For example, after you store the P0 value and press
FUN to store it, then the digital display would still show P0. If you want to
adjust P1, press INC+, until the display shows P1 and then press FUN to
select P1. If you do not need to change another setting, press the LEARN
button to exit.
P0 - Sets the soft start time
for the actuators from 0-6 seconds.
Recommendation: Leave at the default of 2 seconds.
P1 - P4 sets the level of stall force
which determines how hard and long the gate will push
against an obstruction before reversing.
Unless you need to change them, leave these at the factory default settings as follows: