23
Factory default is set to 0 which is .5 second. 1 is 5 seconds.
PC – Radio Receiver Mode -
Controls whether the wireless keypad and remote
transmitters will open a Single gate or Double gate
0 = Disables opening by the remote or keypad.
1 = Single gate mode
2 = Double Gate Mode
3 = Top Left Remote button only opens Primary side; Top Right remote button opens both
sides
Recommendation: Set this to "1" for a Single gate or "2" for Double gates.
NOTE: Keypad should be set to channel 2 for a double gate.
Pd -
S
afety photo beam setting
Specifies which type of contact the safety photo beam is using.
00 Normally Closed “N.C.”
01 Normally Open “N.O”.
Recommended: 01 for Normally Open “N.O.”
Po - Reset
the control board to factory settings