background image

12 

 

extends out of the bottom of the control box.  Connection should be made 
in a weather tight junction box. 

All high voltage wiring must be in 

conduit.   
 

The cables for the safety photo beam, exit wand, wired keypad and wired 
intercom are not required to be placed in conduit but it is highly 
recommended to do so in order to protect them and to be able to more 
easily replace them.   
 
It is highly recommended to ground the system with a grounding rod.  
Attach the grounding wire to the GND connection.    
 

 

 

SOLAR POWER 

 

 

Alternatively, this system can be powered by batteries charged with a solar 
panel via a charge controller.  Two 12Vdc 7ah (amp hour) batteries must 
be wired IN SERIES to provide 24V DC.  (See wiring diagram.) 
 

Important:

  Connect the charge controller to the batteries 

FIRST, and then connect the solar panel to the charge 
controller.  This tells the charge controller that the voltage is 
24V DC. 

 
Check the batteries regularly to see if they are holding a full charge.  If 
not, remove them and put them on an automotive/motorcycle battery 
charger.  This is especially important in the beginning of fall and again at 
the beginning of winter when the days are short and there could be more 
cloudy weather.  Important:  When you replace the batteries, be sure to 
disconnect the solar panel from the charge controller and then connect the 
batteries, and then re-connect the solar panel.  This tells the charge 
controller that the voltage is 24V DC. 
 

Solar Charge Controller 

Содержание GATEMASTER 900 HD

Страница 1: ...1 AGA GATEMASTER 900 HD AGA GATEMASTER 900 HD Installation Manual...

Страница 2: ...d with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions Failure to follow installati...

Страница 3: ...ny components unless shown in this manual Do not try to manually open or close the gate without pulling up the release lever If there is a failure that cannot be solved and is not mentioned in this ma...

Страница 4: ...length 12 inches Power supply 110V AC converted to 24V DC with built in transformer Nominal input power 2A Maximum operating current 5 5A for maximum 10 seconds Maximum gate weight 500 lbs Maximum gat...

Страница 5: ...to shrink and expand The hinges cannot be mounted in the center of a column The angle will be too wide If you mount on a column make sure that the gate hinges are within 4 of the back of the column If...

Страница 6: ...6...

Страница 7: ...gate open NOTE The operator shaft will be fully extended when the gate is closed and fully retracted when the gate is open Note that there is not a limit setting on the control board Simply manually...

Страница 8: ...release lever then extend the arm all the way out The arm will be in this completely extended position when the gate is closed Determine where you will mount the operator It is better to be near the...

Страница 9: ...ng points Making sure the bracket is level drill four 3 8 holes through the hinge post and fasten the bracket with nuts and washers Note Drilling and bolting all the way through the post is the strong...

Страница 10: ...will be in this completely retracted position when the gate is closed The arm will be completely extended when the gate is open Determine where the operator will be mounted It is better to place it n...

Страница 11: ...is the strongest method but if it is not possible to drill through the post you could use quarter inch self tapping screws If that is necessary regularly check that the screws are tight Drill and bol...

Страница 12: ...amp hour batteries must be wired IN SERIES to provide 24V DC See wiring diagram Important Connect the charge controller to the batteries FIRST and then connect the solar panel to the charge controlle...

Страница 13: ...up Battery backup is not required In the event of a power failure there is a manual release lever on the top of each operator arm which allows the gates to be opened manually Turn the key and lift the...

Страница 14: ...onal accessory wires Connect the Operator Arms Cables to the Control Board Bi Parting Double Gate Connect cable from the Primary operator arm on the near side of the driveway Connect the Black wire to...

Страница 15: ...E Have the keypad in hand at the gate control box when programming Do not mount keypad on gooseneck mounting post yet Step 1 Program the keypad to the gate operator Enter 0000 to enter programming mod...

Страница 16: ...may be mounted on brackets mounted to the gate posts or on small metal or wood stakes on each side of the driveway For a double gate photo eyes are mounted to shoot the beam directly across the drive...

Страница 17: ...s triggered to open Dig a shallow trench and bury the exit sensor It is not necessary to use a PVC conduit but it is a good idea in order to protect it and to make it easier to replace Wiring Instruct...

Страница 18: ...its own radio receiver and two remotes come with the system In some cases you might want to add another receiver for example if you want to use a different wireless keypad such as the Liftmaster KPW5...

Страница 19: ...19...

Страница 20: ...output is used for connecting photo eye sensor Continuous output current 200mA 8 24V battery output is used for connecting the backup battery 9 24V battery output is used for connecting the backup bat...

Страница 21: ...it means the system is normal Basic Function Setting Method To begin programming press and hold the FUN function button until the digital display shows P0 Press INC or DEC to increase or decrease the...

Страница 22: ...t is 0 seconds P8 Sets the close delay time for the gate to close when utilizing a magnetic lock This staggers the gates so that they don t close at the same time Can be set from 0 to 10 seconds 1 mea...

Страница 23: ...t this to 1 for a Single gate or 2 for Double gates NOTE Keypad should be set to channel 2 for a double gate Pd Safety photo beam setting Specifies which type of contact the safety photo beam is using...