This manual covers operator instructions for operating the VGC-3 gate from the Operator 
Control.  It  assumes  the  gate  has  been  installed,  wired  and  setup  so  that  normal 
positioning of the gate may begin. 

See  the  separate 

VGC  Electrical  Wiring  and  Setup 

manual  if  the  installation  is  not 

complete. 

 

VGC-3

 

Operating, Customizing 

And Troubleshooting 

Содержание VGC-3

Страница 1: ...ting the VGC 3 gate from the Operator Control It assumes the gate has been installed wired and setup so that normal positioning of the gate may begin See the separate VGC Electrical Wiring and Setup m...

Страница 2: ...he gate will follow the arrow keys requested position 6 The CLOSE button will immediately close the gate from any open position The gate will not open again until the OPEN button is pressed regardless...

Страница 3: ...d the gate will open to the preset position and stop In summary when the gate is closed it will not respond to changing the preset percent of opening Pressing the Open button opens the gate to the pre...

Страница 4: ...s of sensor activity when the motor is running it stops backs up a bit and retries forward movement to see if it can break loose or dislodge an obstruction If it is successful it continues to its dest...

Страница 5: ...ed or power is interrupted Net Address Network Setup Enables network communication by selecting a character for the address Setting this character to a blank disables the network for this control Gate...

Страница 6: ...pts were made to move the gate but were unsuccessful Most likely this is caused by mechanical interference in the gate but could also be an improperly adjusted wheel sensor on the gear reducer Closing...

Страница 7: ...position set by the VGC preset number The gate will follow the arrow key changes to the request number as long as the relay contact remains closed When the relay contact opens the gate will close The...

Страница 8: ...rstand how and when control should be transferred Note 1 Roller chain reductions may be used to increase force at the cost of speed 2 LCD screen update slows down below 32 F although gate operation is...