22
P1 - 6 (applies to secondary arm at low speed)
P2 -10 (applies to secondary arm at high speed)
P3 - 6 (applies to primary arm at low speed)
P4 -10 (applies to primary arm at high speed)
P5 - Sets the high-speed running time
. This allows the gate to run at its highest speed for
however many seconds you set before slowing down. Recommendation: Start at 11 and
work either up or down from there.
Factory Default is 5 seconds.
P6 – Swipe Auto Close.
Sets the
auto close time
in seconds when the gate is opened by an
exit sensor or wired
keypad
that is wired into terminal #4
SWIPE
.
Factory default: The gate will automatically close after 10 seconds.
Turn OFF auto close with a setting of 0.
Turn ON auto close by setting this at 1 to 99 seconds.
When gate is open and the auto close timer is on, the blue led blinks.
P7 - Sets the open delay time
for the Primary gate to open when utilizing a
magnetic lock.
It staggers the gates so that they don't open at the same time.
Can be set from 0 to 10 seconds.
A setting of 1 means the Secondary Arm (MOTOR1) starts to open 1 second before the
Primary Arm starts to open.
Factory default is 0 seconds.
P8 - Sets t
he
close delay time
for the gate to close when utilizing a
magnetic lock
.
This staggers the gates so that they don't close at the same time.
Can be set from 0 to 10 seconds.
1 means the Primary Arm (MOTOR2) starts to close 1 second before the Secondary Arm
(MOTOR1.)
Factory default is 0 seconds.
P9 – Receiver Auto Close
Sets the
auto close time
in seconds after the gate has been opened by a
remote transmitter
or wireless keypad
.
Turn off auto close with a setting of 0.
Turn ON auto close with a setting of 1 to 99 seconds.
Factory default is 0 seconds.
When gate is open and the auto close timer is on, the blue led blinks.
PA -
Used when connecting a flashing light or alarm.
0 Alarm sounds when the third remote button is pressed and held, lamp lights for 30 seconds
1 Alarm sounds when the third remote button is pressed and held, lamp lights while gate is
moving
2 Alarm sounds when the third remote button is pressed once and stops when it pressed
again; lamp lights for 30 seconds
3 Alarm sounds when the third remote button is pressed once and stops when it pressed
again, lamp lights while gate is moving
Factory default is 0
Pb – Solenoid Lock Time
Used to extend the time a gate would remain locked (if using a
lock) before the gate starts opening.
0 =
one half second, 1 is 5 seconds