9
◼
Using a clamp, mount the gate bracket onto the gate.
Do not drill and bolt yet.
◼
Attach the operator arm to the brackets again.
◼
With the release lever up, move the gates manually open and closed and adjust the
brackets until the gate opens and closes in the correct position. This cannot be changed
once finally drilled and bolted. Be sure the actuator is level and the gates are in the
desired position. The post bracket will self-adjust to the correct position and can then be
tightened securely. (Remember, you had left it hand tight.) Move the gate bracket as
needed.
◼
Test the bracket positions a few times and when satisfied they are in the proper position,
tighten the bracket bolts.
◼
Mount the post bracket onto the post with bolts.
-
Place the post bracket on the post and mark the drilling points. Making sure the
bracket is level, drill four 3/8 holes through the hinge post and fasten the bracket
with nuts and washers.
-
Note: Drilling and bolting all the way through the post is the strongest method, but
if it is not possible to drill through the post, you could use quarter inch self-tapping
screws. If that is necessary, regularly check that the screws are tight.
◼
Drill and bolt the gate attach bracket permanently. There are no limits
to set, so at this point the actuator is ready to be powered up and used.
PUSH-To-Open Installation Steps
NOTE: This is for a gate that will swing out towards the street. The operator is mounted on
the inside and pushes the gate open.
The operator shaft will be fully extended when the gate is open and fully retracted when the
gate is closed.
Note that there are no “Limit Settings” via the control board. You will manually adjust the
operator brackets until they are in the desired position.
◼
Start with the gate panels in the closed position.