Using a clamp, mount the gate bracket onto the gate.  

Do not drill and bolt yet.

 

 

 

Attach the operator arm to the brackets again. 

 

 

With the release lever up, move the gates manually open and closed and adjust the 
brackets until the gate opens and closes in the correct position. This cannot be changed 
once finally drilled and bolted. Be sure the actuator is level and the gates are in the 
desired position. The post bracket will self-adjust to the correct position and can then be 
tightened securely. (Remember, you had left it hand tight.) Move the gate bracket as 
needed. 

 

 

Test the bracket positions a few times and when satisfied they are in the proper position, 
tighten the bracket bolts. 

 

 

Mount the post bracket onto the post with bolts.   

 

-

 

Place the post bracket on the post and mark the drilling points.  Making sure the 
bracket is level, drill four 3/8 holes through the hinge post and fasten the bracket 
with nuts and washers. 

    

-

 

Note:  Drilling and bolting all the way through the post is the strongest method, but 
if it is not possible to drill through the post, you could use quarter inch self-tapping 
screws.  If that is necessary, regularly check that the screws are tight. 

 

 

Drill and bolt the gate attach bracket permanently. There are no limits 
to set, so at this point the actuator is ready to be powered up and used. 
 
 
 

 

 
 
PUSH-To-Open Installation Steps 

 
NOTE:  This is for a gate that will swing out towards the street.  The operator is mounted on 
the inside and pushes the gate open.   
The operator shaft will be fully extended when the gate is open and fully retracted when the 
gate is closed. 
Note that there are no “Limit Settings” via the control board.  You will manually adjust the 
operator brackets until they are in the desired position. 

 

 

Start with the gate panels in the closed position. 

 

Содержание GATEMASTER 900 HD

Страница 1: ...1 AGA GATEMASTER 900 HD AGA GATEMASTER 900 HD Installation Manual...

Страница 2: ...d with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions Failure to follow installati...

Страница 3: ...ny components unless shown in this manual Do not try to manually open or close the gate without pulling up the release lever If there is a failure that cannot be solved and is not mentioned in this ma...

Страница 4: ...length 12 inches Power supply 110V AC converted to 24V DC with built in transformer Nominal input power 2A Maximum operating current 5 5A for maximum 10 seconds Maximum gate weight 500 lbs Maximum gat...

Страница 5: ...to shrink and expand The hinges cannot be mounted in the center of a column The angle will be too wide If you mount on a column make sure that the gate hinges are within 4 of the back of the column If...

Страница 6: ...6...

Страница 7: ...gate open NOTE The operator shaft will be fully extended when the gate is closed and fully retracted when the gate is open Note that there is not a limit setting on the control board Simply manually...

Страница 8: ...release lever then extend the arm all the way out The arm will be in this completely extended position when the gate is closed Determine where you will mount the operator It is better to be near the...

Страница 9: ...ng points Making sure the bracket is level drill four 3 8 holes through the hinge post and fasten the bracket with nuts and washers Note Drilling and bolting all the way through the post is the strong...

Страница 10: ...will be in this completely retracted position when the gate is closed The arm will be completely extended when the gate is open Determine where the operator will be mounted It is better to place it n...

Страница 11: ...is the strongest method but if it is not possible to drill through the post you could use quarter inch self tapping screws If that is necessary regularly check that the screws are tight Drill and bol...

Страница 12: ...amp hour batteries must be wired IN SERIES to provide 24V DC See wiring diagram Important Connect the charge controller to the batteries FIRST and then connect the solar panel to the charge controlle...

Страница 13: ...up Battery backup is not required In the event of a power failure there is a manual release lever on the top of each operator arm which allows the gates to be opened manually Turn the key and lift the...

Страница 14: ...onal accessory wires Connect the Operator Arms Cables to the Control Board Bi Parting Double Gate Connect cable from the Primary operator arm on the near side of the driveway Connect the Black wire to...

Страница 15: ...E Have the keypad in hand at the gate control box when programming Do not mount keypad on gooseneck mounting post yet Step 1 Program the keypad to the gate operator Enter 0000 to enter programming mod...

Страница 16: ...may be mounted on brackets mounted to the gate posts or on small metal or wood stakes on each side of the driveway For a double gate photo eyes are mounted to shoot the beam directly across the drive...

Страница 17: ...s triggered to open Dig a shallow trench and bury the exit sensor It is not necessary to use a PVC conduit but it is a good idea in order to protect it and to make it easier to replace Wiring Instruct...

Страница 18: ...its own radio receiver and two remotes come with the system In some cases you might want to add another receiver for example if you want to use a different wireless keypad such as the Liftmaster KPW5...

Страница 19: ...19...

Страница 20: ...output is used for connecting photo eye sensor Continuous output current 200mA 8 24V battery output is used for connecting the backup battery 9 24V battery output is used for connecting the backup bat...

Страница 21: ...it means the system is normal Basic Function Setting Method To begin programming press and hold the FUN function button until the digital display shows P0 Press INC or DEC to increase or decrease the...

Страница 22: ...t is 0 seconds P8 Sets the close delay time for the gate to close when utilizing a magnetic lock This staggers the gates so that they don t close at the same time Can be set from 0 to 10 seconds 1 mea...

Страница 23: ...t this to 1 for a Single gate or 2 for Double gates NOTE Keypad should be set to channel 2 for a double gate Pd Safety photo beam setting Specifies which type of contact the safety photo beam is using...