Ndrive HL User’s Manual
Technical Details
www.aerotech.com 3-13
3.3.1. End of Travel Limit Inputs
Two of the three limit inputs are end-of-travel sensing (CW Limit and CCW Limit) while
the third is a reference limit (Home Limit). All of the end-of-travel limit inputs accept 5-
24 volt DC logic signals. The pin assignment for the connector is shown in the table
below.
Alternatively, opto-isolated user inputs 8-10 may be used as the end-of-travel limit
inputs, see Section 3.1.3.
See Table 3-12 for the mating connector part number.
Table 3-13.
End of Travel Limit Inputs Pin Assignment on Connector J207
Pin #
Label
Description
In/Out/Bi.
12
CW/+Lmt.
Clockwise End of travel limit
Input
16
+5 Volt
+5 Volt Power for Limit Switches (500mA.
max.)*
Output
20
Common
Signal Common for Limit Switches
N/A
22
Hm.Lmt.
Home Switch Input
Input
24 CCW/-Lmt.
Counterclockwise
End of travel limit
Input
* Total user +5 V power is limited to 500 mA, by an internal re-settable semiconductor fuse.
Figure 3-7.
End of Travel Limit Inputs