- 66 -
10.2001 A. B.
599 51 21 26
EN
12.4 Legend
D
T
+
10
=
heating time + 10 minutes
ctrol
=
recirculation 2800 1/min
PulsN
=
pulsed washing 1 / pulsed washing 2
New Fan
=
fan with condenser drying
VGA
=
fully integrated dishwasher
13. Measuring points
7-pole connector
Pin
Widerstand
Attention!
With the 7-pole connector clamps 7 and 5
have the mains voltage. When measuring
the resistance the mains plug must be
absolutely unplugged or the fuse turned
off.
circulation pump main winding m8
1 - 2 35
Ω
- 59
Ω
drain pump m3 normal
5 - 6 170
Ω
drain pump m3 float switch f 16.1 or safety
pressure switch fS has reacted
5 - 7 170
Ω
NTC tem perature sensor
temperature/resistance
20 °C / 6032
Ω
25 °C / 4829
Ω
(only w ith fully electronic
30 °C / 3891
Ω
dishw ashers)
40 °C / 2573
Ω
50 °C / 1741
Ω
55 °C / 1444
Ω
60 °C / 1204
Ω
65 °C / 1009
Ω
70 °C / 849
Ω
Measure all resistances with
plugged-off connector.
filling solenoid s11
4
k
W
regenerating solenoid s9
3k
W
heating contactor c2
6,7
k
W
tachymetric generator g1
213
W
reed switch salt b92 with missing salt
0
W
pressure switch fN with level
0
W
thermal sensor NTC
rotary slide drive 1 - 3 9 k
W
positioning contact 1 - 2
upper sprayarm ¥W, lower sprayarm 0
W
turbidity sensor
1
-
2
6
- 11,4 V
1
-
3
clear water 4,3 V
turbid water in prewash
<
3
V
turbid water in intermediate rinsing < 3,8 V
3-pol. Stecker
1 2 3
7-pole connector
1
2
7
3
4
6
5
2
7
3
4
6
5
1
2
3
4
5
1
1
4
2
3
1
1
4
1
4
1
4
KL5
M2.1
S5
V2.1
V2.2
R2
M2.2
Q2
N2
T2
E5
3-pole
connector
4-pole
connector
to the input
module
to the input
module
4-pole
connector
4-pole
connector
Front side of board
3-pole connector
fan 1 - 3
869
W
Содержание ATAG VA4511AT
Страница 1: ...ATAG VA6011LT PT VA4511AT VA5511AT...
Страница 19: ...19 10 2001 A B 599 51 21 26 EN Circuit diagram 111 569 200...
Страница 20: ...20 10 2001 A B 599 51 21 26 EN Circuit diagram 111 568 900...
Страница 21: ...21 10 2001 A B 599 51 21 26 EN Legend...
Страница 23: ...23 10 2001 A B 599 51 21 26 EN Circuit diagram 111 527 600...
Страница 67: ...AEP Home Products Impact 54 6921 RZ Postbus 249 6920 AE Duiven Nederland...