- 29 -
10.2001 A. B.
599 51 21 26
EN
-
Cycle End
o
The confirmation LED of the cycle key and the option key of the finished cycle continue
to light.
o
Depending on model, the LED “end” will light resp. the digit “0” will be indicated by the 7-
segment display at the end of the cycle. If existing, the LED “running time” will go out.
o
Only for “VGA” models it is valid that the LED of the cycle key will be cancelled and the
LED “end” will light.
o
In addition, a buzzer will indicate acoustically, when the cycle end has been reached.
(buzzer 10 sec on – 270 sec off – 10 sec on). This acoustic indication will repeat 3
times at maximum and can be switched off optionally by a key combination.
(see chapter “Switching off the Buzzer”)
o
The cycle stored in the control unit will be cancelled.
o
When the cycle end has been reached and the door opened and closed again, the
appliance is automatically again in the “pre-start” mode, i.e. a new cycle could be set
again immediately.
o
The appliance must be switched off by the ON/OFF key.
4.5
Set the Water Softener
In order to avoid lime scale on dishes and in the dishwasher it is necessary to rinse the water with
soft, i.e. decalcified water. Therefore, the dishwasher has a water softener, which decalcifies tap
water from a hardness of 4 °d (German degree) onward with the help of special salt.
Set the water softener according to the table to that level which corresponds to the water hardness
in the residential district. The water softener is set mechanically with the hardness area switch and
in addition electronically with the keys of the control panel.
1)
(°d) German degree, measure for water hardness
2)
(mmol/l) millimol per liter, international unit for water hardness
*)
setting by factory
Water Hardness
Setting of Hardness Level
Number of
Flashing
Signals
in °d 1)
in mmol/l 2 ) range
mechanical
electronical
51 - 70
9.0 – 12.5
43 - 50
7.6 – 8.9
37 - 42
6.5 – 7.5
29 - 36
5.1 – 6.4
1
23 - 28
4.0 – 5.0
IV
9
8
7
6
5
9
8
9
6
5
19 - 22
3.3 – 3.9
15 - 18
2.6 – 3.2
III
4
3*
4
3
11 - 14
1.9 – 2.5
II
2
2
4 - 10
0.7 – 1.8
I/II
1
1
below 4
below 0.7
I
0*
0
no salt
required
10
Содержание ATAG VA4511AT
Страница 1: ...ATAG VA6011LT PT VA4511AT VA5511AT...
Страница 19: ...19 10 2001 A B 599 51 21 26 EN Circuit diagram 111 569 200...
Страница 20: ...20 10 2001 A B 599 51 21 26 EN Circuit diagram 111 568 900...
Страница 21: ...21 10 2001 A B 599 51 21 26 EN Legend...
Страница 23: ...23 10 2001 A B 599 51 21 26 EN Circuit diagram 111 527 600...
Страница 67: ...AEP Home Products Impact 54 6921 RZ Postbus 249 6920 AE Duiven Nederland...