![AEP Networks ATAG VA4511AT Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/aep-networks/atag-va4511at/atag-va4511at_user-manual_2861303052.webp)
- 52 -
10.2001 A. B.
599 51 21 26
EN
10. Regeneration
The water chamber for regeneration (3) contains 350 ml water. During regeneration, the
regeneration valve (11) is energized. The 350 ml water runs into the salt container (9) and
mixes with the salt to form a brine solution.
In the top of the salt container there is an opening with a small filter, from here the brine
solution passes through a non-return valve (10) and enters the softener (8) where the
resins are regenerated.
The softener has 10 settings and can be adjusted to suit the degree of water hardness.
The adjustment of the water hardness is described in the short list of service functions.
10.1 Regenerating Phases and Condenser Drying
Phase Water
Hardness
Remaining
Water Hardness
Salt Regenerating
depending on
Regenerating after
mech. electr.
°d
°F
°d
°F
need after
Final Rinse Washing
0
0
< 4
< 7
428 liter
X
0
1
4 - 10 7 - 18
1 - 5
2 - 9
90 g
130 liter
X
0
2
11 - 14 19 - 25 2 - 5
4 - 9
90 g
94 liter
X
0
3
15 - 18 26 - 33 3 - 5
5 - 9
90 g
70 liter
X
0
4
19 - 22 34 - 40 3 - 5
5 - 9
90 g
53 liter
X
0
5
23 - 28 41 - 51
3 - 6
5 - 11 90 g
37 liter
X
1
6
29 - 36 52 – 65 4 - 6
7 - 11 90 g
20 liter
X
1
7
37 – 42 66 – 76 3 - 7
5 - 11 90 g
15 liter
X
1
8
43 – 50 77 – 91 4 - 7
7 - 13 90 g
10 liter
X
1
9
51 - 70 92 – 127
-7 -13
100
g
3 liter
X
X
Easy, Control Electronic 111 573 600 / 111 577 800
Phases Function
Time
Comment
1
drying, pumping
5 sec
2
regenerating, drying
240 sec
*
3
pumping, drying
15 sec
4 drying 300
sec
5
drying, filling
15 sec
* rinse out softener
6 drying 5
sec
*
7
drying, filling
to level
* rinse out softener
8
drying, pumping, filling
5 sec
* rinse out softener
9
drying, pumping
5 sec
*
10 drying 180
sec
11
drying, filling
15 sec
cool down condenser and rinse out
softener
12
drying, pumping
15 sec
13 drying 660
sec
14
drying, pumping
15 sec
* only when regenerated demanding on need
Содержание ATAG VA4511AT
Страница 1: ...ATAG VA6011LT PT VA4511AT VA5511AT...
Страница 19: ...19 10 2001 A B 599 51 21 26 EN Circuit diagram 111 569 200...
Страница 20: ...20 10 2001 A B 599 51 21 26 EN Circuit diagram 111 568 900...
Страница 21: ...21 10 2001 A B 599 51 21 26 EN Legend...
Страница 23: ...23 10 2001 A B 599 51 21 26 EN Circuit diagram 111 527 600...
Страница 67: ...AEP Home Products Impact 54 6921 RZ Postbus 249 6920 AE Duiven Nederland...