Fan data
230V, 50-60Hz
Thyro-A Type current 50Hz Type current 60Hz Air volume
Noise level
1A...280 F
0.22A
0.22A
120 m
3
/h
67dB(A)
1A...350 F
0.22A
0.22A
120 m
3
/h
67dB(A)
1A...495 F
22W at 115/230V and/or 50/60Hz 288m
3
/h
58dB(A)
1A...650F
22W at 115/230V and/or 50/60Hz 288m
3
/h
58dB(A)
1A...1000F
0.29A
0.35A
880m
3
/h
58dB(A)
1A...1400F
0.29A
0.35A
880m
3
/h
58dB(A)
1A...1500F
0.29A
0.35A
880m
3
/h
58dB(A)
2A...280F
0.50A
0.38A
200m
3
/h
70dB(A)
2A...350F
0.50A
0.38A
200m
3
/h
70dB(A)
2A...495 F
0.31A
0.25A
380 m
3
/h
49dB(A)
2A...650 F
0.31A
0.25A
380m
3
/h
49dB(A)
2A...1000 F
0.56A
0.79A
1970m
3
/h
69dB(A)
2A...1400 F
0.56A
0.79A
1970m
3
/h
70dB(A)
2A...1500 F
0.56A
0.79A
1970m
3
/h
70dB(A)
3A...280 F
0.38A
0.38A
260m
3
/h
70dB(A)
3A...350 F
0.50A
0.38A
260m
3
/h
70dB(A)
3A...495 F
0.29A
0.35A
880m
3
/h
58dB(A)
3A...650 F
0.29A
0.35A
880m
3
/h
58dB(A)
3A...1000 F
0.56A
0.79A
1970m
3
/h
69dB(A)
3A...1400 F
0.56A
0.79A
1970m
3
/h
70dB(A)
3A...1500 F
0.56A
0.79A
1970m
3
/h
70dB(A)
The fans must run when the device is on, connection to X7.
Содержание THYRO-A
Страница 28: ...28 Possible settings in THYRO TOOL FAMILY ...
Страница 39: ...39 EN l l Type plate 4 2 DIP switches S1 S1 10 S1 9 S1 8 S1 7 S1 6 S1 5 S1 4 S1 3 S1 2 S1 1 off on ...
Страница 70: ...70 Example 4 controllers e g with 100A load triggering approx 30 contents of Sync_Adr 0 100 25 50 75 ...
Страница 89: ...89 EN 10 Type overview Thyro A 1A 16 H 30 H Thyro A 1A 45 H 60 H ...
Страница 90: ...90 75 190 Thyro A 1A 100 H Thyro A 1A 130 H 170 H M 10 for grounding ...
Страница 91: ...91 EN Thyro A 1A 280 HF M 10 for grounding Thyro A 1A 350A To unlock push spring hook to the right ...
Страница 92: ...92 Thyro A 1A 495A 650A Thyro A 1A 1000A 1500 A ...
Страница 95: ...95 EN Thyro A 2A 280 HF M 10 for grounding Thyro A 2A 350A To unlock push spring hook to the right ...
Страница 96: ...96 Thyro A 2A 495 650HF Thyro A 2A 1000 1500HF ...
Страница 97: ...97 EN Dimension drawing Thyro A 3A with 16A 30A The dimension drawings are for type H RLP1 ...
Страница 98: ...98 Dimension drawing Thyro A 3A with 45A 60A The dimension drawings are for type H RLP1 ...
Страница 99: ...99 EN Dimension drawing Thyro A 3A with 100A The dimension drawings are for type H RLP1 ...
Страница 100: ...100 Dimension drawing Thyro A 3A with 130A 170A The dimension drawings are for type H RLP1 ...
Страница 101: ...101 EN Dimension drawing Thyro A 3A with 280A The dimension drawings are for type H RLP1 ...
Страница 103: ...103 EN Thyro A 3A 1000 1500HF Thyro A 3A 495 650HF ...