Error
Possible cause
Solution
Display readability
temporarily impaired
n
ambient temperature lies out-
side the permissible range
n
poor contrast setting
n
Ensure a permissible ambient
temperature according to the
technical data.
n
Adjust the contrast setting.
Battery is not charged
solar module not connected
Connect the solar module.
short circuit at solar module con-
nection
Rectify short circuit.
incorrect solar module voltage
Use a solar module of a suitable
voltage.
Notice
The module voltage must be a
factor of 1.15 times larger than the
current battery voltage in order to
charge the battery.
solar module defective
Replace the solar module.
system consumption higher than
the recharging rate
Reduce consumption.
battery fully charged.
The controller switches itself off
when the battery is fully charged.
the device is not switched on
Switch on the device via
Main
menu
▶
Device on/off
.
The charging power,
charging current and
battery voltage remain
low, despite good solar
irradiation and correct
installation of the solar
module and battery
controller possibly defective
Contact your installer.
Battery voltage very
low
n
battery excessively discharged
by consumers (deep-discharge
protection not installed)
n
battery is defective
n
Charge the battery with an
external charger.
n
Replace the battery.
Battery voltage is sig-
nificantly greater than
the nominal system
voltage
controller possibly defective
Contact your installer.
GB
749.126 | M02 | 2013-11-13