4.
Use the screws/dowels supplied to fasten the controller to the mounting surface.
60
60
60
60
1
3
3
3
3
2
2
1
Fig. 2: Fastening openings
①
/
②
and free space
③
4.3 Establishing the electrical connections
ATTENTION!
Always make connections in the following sequence:
1. First connect the load and then the source.
Example: First connect the cable to the controller and then to the battery.
2. Connect the positive pole first then the negative pole.
Example: First connect B+ then B–.
Note
Use the cable pass-through holes plugged with rubber stops on the bottom of the casing as fol-
lows:
–
2 large cable pass-through holes for the battery cables
5 medium cable pass-through holes for the module and PE cables
3 cable pass-through holes for the sensor cables (1 as a reserve)
–
Feed each cable through the corresponding cable pass-through hole lying opposite to the
cable connection, see Fig. 1, p. 8.
–
Use a screwdriver to punch a hole in the rubber stop of the respective cable pass-through
hole.