1.3 Scope of delivery
MPPT 6000:
n
Device (MPPT 6000)
n
Fastening set (screws, dowels)
n
Socket, 2-pin, green, for connecting the battery voltage sensor cable
n
Operating instructions
1.4 Proper usage
The solar charge controller, hereinafter named as the
controller or device, may only be used in
stand-alone photovoltaic systems for charging and controlling the following types of battery.
MPPT 6000: Lead-acid batteries
The following also applies:
n
The controller must not be connected to the public electricity grid.
n
Only solar modules may be connected to the solar module connections.
n
Possible system voltages (battery voltages): 12 V, 24 V, 48 V (automatic detection) and 36 V,
60 V (manually set).
n
The controller performs the following tasks:
–
Maximisation of power extraction from the modules via an integrated MPP tracker
–
Controlling the charging process
–
Recording yield and system data
1.5 Markings
1.5.1 Symbols for warnings and notices
Symbol
Description
Location
general danger warning
Manual
Danger from electricity
Manual
Read the manual before using the product
Device
Danger from hot surfaces
Manual
1.5.2 Keywords
The following keywords are used together with corresponding symbols for warnings and notices.
Keyword
Description
Danger
immediate danger of death or serious bodily injury
Warning
possible danger of death or serious bodily injury
Caution
possible danger of light or medium bodily injury
GB