75
Empying the condensation water container
DANGER! RISK OF ELECTRIC SHOCK!
If a full condensation water spills over, water can get in contact with the electric
components of the sunbed. Empty the condensation water container as soon
as the Error message “E 07” appears on the display.
The condensation water container collects the condensation water from the
AC. The condensation water container is located inside the sunbed close to
the headend side.
Disconnect the unit from the mains supply with the mains disconnection
switch and secure with lock and key against accidental reconnection.
Remove front cover.
– Get a soft support for storage of the front cover ready.
– Loosen the screws at the front cover.
– Lift the front cover for about an inch.
– Pull the brackets out of the slots at the sunbed supports.
– Store the front cover.
Take the condensation water container out of the sunbed.
– Take off the lid of the container.
Empty the condesation water container.
Screw the lid onto the container again.
Put the condensation water into the holding in such a way that the
container touches the level sensor (1).
Reassemble the front cover.
– Put the brackets into the slots of the sunbed supports.
– Push the front cover against the sunbed bench and tighten screws.