28
From the footend side, push the drip pan for the condensation water
below the condensation water discharge of the AC unit.
Push the front holding bracket against the AC unit and fix with screws to
the groundplate.
ATTENTION!
Danger caused by leaking condensation water.
Push the drip pan below the condensation water discharge.
Put condensation water pump into the drip pan and connect.
Connect to the condensation water pump
- the connection cable
- the discharge hose connecting to the condensation water
container.
Push the flat plug into the connection terminals of the pump.
Push the discharge hose onto the hose nozzle of the pump .
Check hose for tight fit.