background image

58

Installation of UV-lamps in the sunbed

 

 

 

Clean the lamps with a  soft leather cloth slightly damped in glass 

cleaner or clear water. 

 

Put the UV lamps into the lampholder (3.).

 

Turn the lamp clockwise by 90° (4.)and make sure that the lamp stamp 

is clearly visible to the viewer.

–  The UV-lamp snaps into the lampholder with a „click“. 

 

After all sunbed UV-lamps have been installed, re-assemble the AC 

acrylic.

 

Lift the sunbed acrylic for a few centimeters..

 

Put the acrylic support back into its place. 

 

Let the sunbed acrylic down onto the sunbed.

Replacement of starters

Starters must be replace whenever lamps start to flicker or do not light up.

 

Disconnect the unit from the mains supply by turning off the the mains 

disconnection switch and secure with lock and key against accidental 

re-connection.

Survey UV-lamps and starters

1

UV-lamp

2

lampholder

3

starter

Disassembly of starter

 

If you need to replace a starter, proceed as follows: 

 

Turn off the mains disconnection switch and secure with lock and key 

against accidental reconnection. 

 

Take the UV-lamp out of the lampholder.

 

Turn the starter by 90° counter clockwise (2).

 

Take out the starter(1).

Содержание ICON

Страница 1: ...mail info auvl de www auvl de www drmueller de FUTURE INDUSTRIES ORIGINAL DR MÜLLER 135 RESEARCH DRIVE MILFORD CT 06460 Phone 203 878 2300 800 376 8537 Fax 203 878 6424 e mail futuremail futureindustries com weww futureindustries com www auvl com OWNER S MANUAL ORIGINALDR MÜLLERHIGHPERFORMANCETANNINGEQUIPMENT ...

Страница 2: ...olumn and top 3 Sunbed acrylic 13 Air exit body cooling top 4 AC Acrylic 14 Nozzle SunFresh 5 Front cover 15 Passive shoulder tanners 6 Acrylic insert with backlighting in front cover 16 Backlighting in top canopy 7 Side cover headend 17 SunFresh hose 8 Fresh air entry headend 18 Fresh air entry footend 9 Emergency stop button 19 Headrest 10 Control panel 20 Loudpeakers ...

Страница 3: ...aust air stack 2 Heat recycling system optional 3 Entry stud for mains supply cable with threaded gland 4 Entry stud for supply cables with threaded gland for timer device and loudspeakers 5 Type label technical notices ...

Страница 4: ...ected option this button reduces the intensity of the facials reduces the intensity of the body cooling reduces the music volume stops the facials or the AC unit stops the SunHaze aroma system 6 Button Active shoulder tanner Not available for ICON 46 7 Button Facials Preselects option for intensity control of facials 8 Button Body cooling top Preselects option for intensity control of body cooling...

Страница 5: ...ystem optional 3 SunFresh container optional 4 Condensation water container optional 5 AC unit optional 6 Ballast Tray inserts 7 Ballast tray with electrical components 8 Power supply for SunFresh purification system 9 Backlighting lamp front cover plate 10 Main PCB Power Control Board with CPU 11 Elec Connection terminals and contact strip ...

Страница 6: ...ual is addressed to service personnel trained and qualified salon personnel and end users Every person who transports assembles starts operates controls maintains cleans disassembles stores or disposes of this unit must make sure that this manual has been read and its contents is fully understood Keep this manual conveniently close to the sunbed for future reference ...

Страница 7: ... was increased customer comfort and a comfortable tanning climate The ICON 46 can also be equipped with an AC unit The control panel allows the user to select several options during a tanning session AC unit optional body Cooling the intensity of the facials in 2 steps music volume the SunHaze aroma system optional the SunFresh system optional The display shows accrued session time In the operator...

Страница 8: ...f installation 7 Safety instructions for operation 7 Safety instructions for transport 7 Safety instructions for cleaning 8 Safety instructions for maintenance 8 Safety instructions for users 9 Emergency Stop button 10 Safety features 10 Mains disconnection scwitch 10 Use of emergency stop button 11 Safety switches 12 Automatic shut off 13 Delivery 14 Technical Data 15 16 Transport 17 18 Assembly ...

Страница 9: ...mbly of sunbed bench 29 Assembly of top canopy 30 Assembly of electric ballast tray 31 Connection of cables 31 Electrical connection 32 Hose connections 32 33 Installation of electric ballast tray 33 Assembly of backlightling in sunbed front 33 Assembly of covers 34 Assembly of covers at rear column and top canopy 34 Aassembly of covers and sunbed bench 34 35 Assembly of covers top canopy 36 Assem...

Страница 10: ...e 52 Maintenance chart 53 Daily inspection prior to first start up 54 Annual inspection or every 1000 hours of operation 55 Replacement of UV lamps 55 Removing UV lamps out of the top canopy 55 56 Installation of UV lamps into the top canopy 56 Removing UV lamps out of the sunbed 56 Installation of lamps into the sunbed 57 Replacement of starters 58 Survey of UV lamps and starters 58 Disassembly of...

Страница 11: ... Replacement of aroma container in the SunHaze system 74 Emptying the condensation water container 75 Replacement of UV lamp in the SunFresh container and refill 76 78 Cleaning 79 Sunbed and top canopy acrylic 79 Surfaces covers of sunbed and top canopy 79 UV lamps and backlighting lamps 79 HID lamps 79 Filters 79 Disassembly 80 Storage 81 Re installation 81 Troubleshooting 82 Error messages 82 Mal...

Страница 12: ...as standard terms in this manual Italic type is used for references to other chapters of interest The following symbols are used refers to steps of action is used for detailed lists Notices recommendations NOTICE Refers to recommendations and other useful information It is not used as a signal word for situations with an increased risk of injury or damage Warning Warning notices about potentially ...

Страница 13: ...ided this situation can result in severe or light injuries This signal word can also be used for possible damages to goods and property ATTENTION Describes a potentially damaging situation If not avoided this situation can result in damage to the equipment goods or property ...

Страница 14: ...documents for all jobs concerning transport assembly maintenance operation and cleaning of the equipment this manual all applicable standards and regulations concerning the safety of the workplace all other applicable standards at place of operation As operator owner of the equipment you must guarantee that all safety instructions are observed only qualified and authorized service personnel assembl...

Страница 15: ...ed in this manual to observe recommended exposure times Always to wear protective eye wear during a tanning session to operate this sunbed only in professional tanning fitness or beauty salons under the supervision of trained and authorized salon personnel to observe all information provided in this manual and explicitly of all safety instructions to observe all applicable federal state and local s...

Страница 16: ...seases with a contraindication of UV light exposure persons with a history of coronary and circulatory problems persons with unspecified health problems persons with a pace maker persons with a transplants under medication with a contraindication to UV light exposure Disregard of recommended expsure times Refusing to wear protective eye wear during a tanning session For damages to goods and persona...

Страница 17: ...embly maintenance jobs cleaning of UV lamps cleaning of HID lamps Electrical connection The following conditions must be fulfilled at the site of installation for fault free operation of the unit wire gauge of mains supply cable and fusage must comply with technical data installation of a mains supply disconnection switch installation of an FI protective switch installation of a time controlled dev...

Страница 18: ...re set up correctly and all safety features are installed for instance sunbed acrylic top canopy acrylic facial filters exhaust air disposal Do not block air entries or ventilation openings Risk of heat damage Before and after each use of the sunbed check unit for visible outer damage or defects and remove immediately Any defects which might affect the safe operation of this unit must be communicat...

Страница 19: ...e unit Use only acrylic cleaner recommended acrylic manufacturers Never use abrasive or corrosive cleaning solutions Safety Instructions for Maintenance All maintenance instructions and intervals must be diligently observed Use only replacement parts as recommended by Advanced UV Light GmbH ...

Страница 20: ...mptoms or adverse skin reactions If the symptoms do not disappear after a short time consult a dermatologist Do not use drugs which promise to tan the skin without UV light exposure in combination with a tanning session This combination may increase the risk of a sunburn Do not use any self tanning creams or lotions These products may contain ingredients which can increase the effects of UV light ...

Страница 21: ...tch must be installed on the site During breaks of operation and after hours the mains supply must be disconnected with the mains disconnection switch The mains disconnection switch must be secured against accidental activation The drawing shows a sample of a mains disconnection switch with lock and key Disconnection of mains supply Turn the mains disconnection switch into position O The mains sup...

Страница 22: ...y The Emergency Stop Button snaps in when activated ICON 46 46 04 VX T To restart the unit the Emergency Stop Button must be unlocked If any unit related defect has caused the Emergency Stop Button to be activated make sure this defect has been corrected Unlock the Emergency Stop Button Acknowledge corresponding error message in the control panel in order to delete the message Unlocking the Emerge...

Страница 23: ...fan per wind flag switch for installation and functioning the unit shuts off after cooling time starts The main fan runs for about 3 minutes until after cooling time has expired Error code E01 is shown in the display Control Panel Display for installation and correct communication with main PCB The unit shuts off Error code E08 is shown in the display In all cases an error code is shown in the disp...

Страница 24: ...e unit is equipped with an automatic shut off device which turns off the unit automatically after 30 minutes of continuous operation This 30 minutes automatic shut off device is also installed in all units sold outside the EU in addition to other applicable local national standards which regulate maximum exposure times ...

Страница 25: ...opy acrylic rear column acrylic AC acrylic Box 2 black coverings for headend and footend shoulder tanner endcaps for top canopy and rear plate Box 3 ballast tray inserts Box 4 exhaust air stack Box 5 bench and sunbed construction box with protective eye wear headrest adapter cable for connection of MP3 player or CD player and this manual The box with accessories shipped within the sunbed on the ba...

Страница 26: ... lamps Facials 4 x Original Dr Müller high pressure lamps 650 W adjustable Air volume and fresh air supply on the site Required opening for fresh air entry on the site diameter 12 Exhaust air volume 1300 CFM Main exhaust air stack diameter 12 length max 12 Electrical connection only for EU standard versions Voltage 240 V 50 Hz 3 ph NPE Power intake without AC unit 46 amps Power intake with AC unit...

Страница 27: ... falling load during transport Due to its heavy weight sunbed components can cause serious bruises by falling or toppling load during transport Wear safety shoes CAUTION Risk of injuries by moving load during transport There is a risk of injuries caused by the load or the transport vehicle Block transportation alleys in such a way that risk of injuries caused by the transport vehicle or the moving...

Страница 28: ...alanced Observe instructions on operation and handling of the lifting device applicable instructions on the prevention of accidents during transport jobs Drive carefully and cautiously to the site of installation Transport with dolly Four persons lift a single box onto the dolly Move the load carefully to the site of installation Four persons lift the box off the dolly Attention Risk of accidents ...

Страница 29: ...to a heavy duty cardboard box fit to carry two additional boxes with components on top The remaining boxes are fixed to a second pallet For assembly at the site of installation all components must be conveyed to the site of installation where they are unpacked and stored for further use The top and sunbed construction must be disassembled in order to transport the single components to the site of in...

Страница 30: ...n such a way that they don t hinder further assembly work Remove loose packing material Take out the boxes with accessories inside the sunbed Store boxes in such a way that they don t hinder further assembly work The box which contains the manual is marked Take out the manual Remove loose packing material and foils Collect packing material for disposal in compliance with applicable environmental s...

Страница 31: ...moved At the front push the top canopy down and hold down Remove the screws at the headend side at the footend side Keep the screws for further use Open the top canopy Disassembly of backlighting lamp in the sunbed front 9 The backlighting lamp 9 is fixed to two holding plates These plates are screwed with two thumb screws to the sunbed construction Unplug the supply cable Loosen the thumb screws a...

Страница 32: ...t and rear side across its whole length the sunbed acrylic sits in a profile groove Two sash locks secure the acrylic against unauthorized opening The sash locks are turned by an Allan key 6 mm A safety switch controls the installation and position of the sunbed acrylic Two 2 persons are needed to remove the sunbed acrylic Open the the two sah locks Turn clockwise by 90 The acrylic can now be pushe...

Страница 33: ...e out of the SunHaze aroma system Push in the blue ring at the connection and hold Pull the hose out of the connection Let go of the blue ring Four 4 persons pull the sunbed bench out of the column Take the sunbed bench and store at a safe place Disassembly of assembly plate The assembly plate is screwed with two thumb screws to the ground plate Take out the water container for the SunFresh system...

Страница 34: ...on water An AC pump sucks the water out of this drip pan and pumps it into the condensation water container Pull the discharge hose out of the hose nozzle at the pump if necessary Unplug the flat plug from the connections at the pump Remove the front holding bracket for the AC unit and store for further use NOTICE The holding bracket also keeps the drip pan below the AC unit in place Pull the drip ...

Страница 35: ...he rear column One screw at the headend one screw at the footend At the front push the top canopy down and keep fast Push the screws through the threaded holes at the headend side at the footend side Turn screws fast Loosen the cable ties which position the supply cables to the top canopy supports Loosen the hose connections to the SunFresh system Blue hose supply hose Green hose discharge hose Pu...

Страница 36: ...wo screws to the rear column Loosen the screws and remove Carry bench supports to the site of installation Transport of rear column to site of installation Four 4 persons carry the rear column to the site of installation Move the column as close as possible to the designated place of installation Allow for enough space at the rear side to perform the following steps Feed cables thourgh the entry s...

Страница 37: ...hrough the screwed cable gland into the column Pull it inwards roll it up and position it in such a way that it does not hinder further assembly and take care that cable does not get pinched or damaged Later on it will be connected to the main control board Put the exhaust air stack onto the exhaust air outlet Use a screwdriver to fasten the exhaust air stack with four screws onto the rear column ...

Страница 38: ... Watch for correct position of bench supports and rear column Watch carefully for correct position of bench supports and rear column Supports and rear column must stand in a right angle position Move the groundplate between the bench supports and hang it into the bench supports If necessary correct position of bench supports Fasten fixing screws for bench supports tight Installation of AC system Th...

Страница 39: ...Danger caused by leaking condensation water Push the drip pan below the condensation water discharge Put condensation water pump into the drip pan and connect Connect to the condensation water pump the connection cable the discharge hose connecting to the condensation water container Push the flat plug into the connection terminals of the pump Push the discharge hose onto the hose nozzle of the pum...

Страница 40: ... column and is thus supported by the column lengthwise At the sides the bench is supported by the bench supports There are two screws at the headend and two screws at the footend Four persons carry the sunbed bench to the sunbed construction and put it onto the bench supports Push the sunbed bench towards the rear column and let it into the rear column Fix the sunbed bench with screws to the bench...

Страница 41: ...ush the latches in the rear into the support fasten screws Perform the hose connections to the SunFresh system blue hose supply hose green hose discharge hose push the blue ring at the hose coupling and hold push the hose into the connection until you have reached the stop position blue hose supply hose green hose discharge hose Let the blue ring go Check the hose for close fit Feed the top canopy ...

Страница 42: ...sonnel and qualified electricians are allowed to perform initial start up of the unit Connection of cables The connection terminals at the cables and the connection terminals on the ballast tray are numbered Terminals with matching numbers are connected Connect the cables to the electric ballast tray Connect the terminal with the number X to the matching terminal X on the ballast tray Connect the A...

Страница 43: ...ntrol device as described in the chapter Assignment of terminals Connect the ballast tray terminals Connect the remaining plugs from top canopy and sunbed to the ballasts on the electric ballast tray See also the chapter Assignment of terminals Connect the control cable from the display to the main control board display terminal on main PCB Hose connections The following components are optional an...

Страница 44: ... into the connection socket on the main control board Installation of electric ballast tray Push the electric ballast tray under the sunbed bench Take care that connected terminals remain connected and that cables do not get pinched or damaged Layout the cables in a safe and neat way Installation of backlighting lamp in the sunbed front The backlighting lamp is fixed onto two holding brackets The h...

Страница 45: ...rews into the key holes of the rear column Push the cover backwards Fasten cover with screw Assemble cover for the top canopy Take the cover and set the fitting pins into the holes of the top canopy frame Fasten cover with three screws Assembly of covers at the sunbed bench The sunbed bench is covered at the headend and at the footend Into the cover at the headend side the passive shoulder tanners ...

Страница 46: ...plate Let the cover down onto the loudspeakers If necessary slightly adjust the cover moving it right and left or back and forth Fasten the cover from below Assemble the cover at the footend side Take the cover and position yourself at the footend Lower the cover at the right hand side and push it into the rear plate Let the cover down onto the sunbed bench If necessary slightly adjust the cover m...

Страница 47: ...e rear side let the top canopy rest on the top canopy frame Adjust the top canopy cover to insert the mounting screws Fasten top canopy cover at the rear side with screws at the front side by locking the fastening latches Assembly of front cover At the bottom the front cover plate is fixed with two hook plates into slots at the right and left bench supports On the top it is fixed with two screws to ...

Страница 48: ... the spring at the slot in the front top canopy profile Turn the profile outwards Lift the top canopy acrylic and from the front put it in position Fit the top canopy arylic into the groove at the rear side of the top canopy Tilt the top canopy acrylic upwards and push it against the front top canopy profile ...

Страница 49: ...lumn Loosen the quick connections at the profile strip Remove profile strip Connect the control panel The supply cable for the control panel must be fed through the small drill hole in the acrylic to the connection plug Lift the rear column acrylic onto the sunbed bench Let the acrylic rest on the front side Push the plugthrough the small opening at the rear side of the rear column acrylic 1 Push th...

Страница 50: ... column acrylic into the groove at the rear side 1 Tilt the acrylic upwards Take care that the control cable for the control panel sits right behind the cover profile Fix the rear column acrylic with the profile strip 2 ...

Страница 51: ...anner Take the neck tanner Adjust into the right position Place it with the notches into the mountings of the black cover Check if neck tanner fits correctly Assembly of AC acrylic The AC acrylic sits under the sunbed acrylic The AC acrylic feeds the cold air through the sunbed and conveys the hot air out of the sunbed Position the AC acrylic into the deepenings of the headend and footend covers ...

Страница 52: ...nbed acrylic The two sash locks must be open To open the sash locks turn clockwise by 90 Lift the sunbed acrylic with the two sash locks pointing to the side Position the sunbed acrylic across the rear edge of the sunbed profile Lower the sunbed acrylic into the front profile groove At the footend side the acrylic is slightly lifted up by the safety switch Push the sunbed acrylic backwards into the ...

Страница 53: ...n 90 Clockwise The acrylic is pushed by the sash look into the front profile groove At the footend push the sunbed acrylic down Close the sash lock at the footend Turn 90 Clockwise The acrylic is pushed by sash lock into the front profile groove ...

Страница 54: ...ia the control panel you have access to the operator s menue In the operator menu you can read out total operating hours select the set ups for operating hours of low and highpressure lamps as well as choose other customized set ups for operating the sunbed NOTICE Set ups can only be accessed or modified when the unit is in stand by mode Turn the mains disconnection switch into position I Push the ...

Страница 55: ...tons and you enter the required value for the operating hours for instance 500 With the button you increase the value shown on the display With the button you diminish the value shown on the display In order to get to the next menu point push the button Music until you reach the required menu point In order to leave the operator menu push the Music button until you have reached the last point in t...

Страница 56: ...x 00 or internal control 01 30 06_00 00 07 00 02 AC unit always OFF 00 AC unit ON at start then optional ON OFF 01 AC unit OFF at start then optional ON OFF 02 07_01 01 08 00 01 Facials optional OFF 00 or Facials always ON 01 08_00 00 09 00 01 Button STOP with intermediate function 00 or button STOP never with intermediate function 01 Stop button deactivated 02 09_01 02 10 00 01 Cleaning function ...

Страница 57: ...h the button START The unit starts The displays shows accrued tanning time If you want to interrupt the tanning session pushthe button STOP The unit stops If you want to continue the tanning session push the button START again NOTICE The tanning session will only continue if preselected tanning time is still available The HID lamps start with a delay time cooling of three minutes OEM set up The un...

Страница 58: ... cooling sunbed The speed of the airflow can be increased or reduced Push the button Body cooling sunbed To increase the air flow push the button To reduce the air flow push the button AC unit The AC unit creates a comfortable tanning climate When the unit starts the AC unit turns on automatically OEM set up To turn the AC unit ON or OFF proceed as follows Push the button AC unit To turn off the AC u...

Страница 59: ...e tanning session can be stopped manually In order to stop the session push the button STOP Activating SunFresh option To activate the SunFresh Watermist option push the button SunFresh Activating SunHaze option To activate the SunHaze option push the button SunHaze Aroma Music volume The volume of the loudspeakers can be steplessly adjusted Push the button Music To increase the volume push the bu...

Страница 60: ...ious damages of eyes and skin Never exceed recommended exposure times Observe the following instructions carefully Observe recommended exposure times as per your individual skin type see chapter Recommended Exposure Times Keep an interval of minimum 48 hours between first two sessions Tan only once a day Do not tan in the natural sun on the day you have already had a tanning session If you are suff...

Страница 61: ...ur physician or dermatologist The following chart helps you to determine your skin type Skin type II III IV Complexion light Light beige beige olive Freckles Few none none none Hair color blonde brown Dark blonde brown Dark brown black Eye color blue green grey grey brown Brown Nipples light darker darkl Tanning rarely average Fast deep Sunburn Frequency always rarely Almost never Minutes until su...

Страница 62: ...sure times can lead to serious skin damage If you do not use the standard lamps as quoted below you may have to adjust exposure times When using other lamps than those recommended by manufacturer with listed exposure times the operator has to make sure that maximum exposure times are in compliance with applicable local national standards and regulations for tanning equipment and exposure times For...

Страница 63: ...7 8 10 8 8 9 10 9 8 10 10 10 9 10 10 11 9 10 10 12 9 10 10 Each following session 9 10 10 Maintenanceaintenance DANGER RISK OF ELECTRIC SHOCK Switch off the mains disconnection switch prior to performing any maintenance jobs Secure the switch with lock and key against accidental turn on DANGER Hot surfaces Risk of burns Low and high pressure lamps get very hot during operation and can cause seriou...

Страница 64: ...ctuer on useful lifetime HID lamps After recommended useful lifetime has expired see chapter Replacement of high pressure lamps and facial filters Observe information of manufacturer on useful lifetime Facial filters Whenever necessary see Replacement of HID lamps and Filters AC acrylic Whenever necessary see AC acrylic Acrylic in top canopy Whenever necessary scratched or damaged see Replacement of...

Страница 65: ...ylic rear column acrylic Damage Top canopy acrylic Damage All air openings and outlets for fresh and exhaust air Free access SunFresh Container Damage Control of functions Component Check for Emergency stop button All UV radiation stops immediately after emergency stop button has been pressed Main ventilation shuts off after after cooling time has expired Timer control device Correct functions Mai...

Страница 66: ... lifetime as recommended by manufacturer has expired or whenever a UV lamps fails or is defective NOTICE Advanced UV Light recommends to replace lamp starters with every second lamp change when conventional non electronic starter type is used Disassembly of UV lamps out of top canopy In order to loosen the screws at the cover profile take a screwdriver push into direction indicated by the arrow 1 a...

Страница 67: ...lamp into the holder 3 Turn the UV lamp by 90 clockwise 4 and make sure that the stamp on the UV lamp is clearly visible to the viewer Tilt the top canopy acrylic upwards until you can hear it click into the top Disassembly of UV lamps out of sunbed If you want to replace a UV lamp in the sunbed proceed as follows Disconnect the mains disconnection switch and secure with lock and key against accid...

Страница 68: ...amps in compliance with applicable environmental regulations and standards CAUTION HEAT RISK FOR THE EQUIPMENT Incorrectly installed reflector lamps can cause heat problems with the equipment and result in serious damage When using reflector lamps make sure that the stamp on the lamp is clearly visible to the viewer ...

Страница 69: ...rt back into its place Let the sunbed acrylic down onto the sunbed Replacement of starters Starters must be replace whenever lamps start to flicker or do not light up Disconnect the unit from the mains supply by turning off the the mains disconnection switch and secure with lock and key against accidental re connection Survey UV lamps and starters 1 UV lamp 2 lampholder 3 starter Disassembly of sta...

Страница 70: ...tarter clockwise by 90 into the lampholder 4 Replacement of sunbed acrylic Installation of new sunbed acrylic The two sash locks must be open To open turn clockwise by 90 Get the new sunbed acrylic into a position suitable for installation Put the sunbed acrylic into the groove along the rear sunbed profile Lower the sunbed acrylic along the groove on the front profile At the footend the sunbed acry...

Страница 71: ...bed acrylic down Keep the sunbed acrylic in this position Close the sash lock at the headend side Turn counter clockwise by 90 The sash lock pushes the sunbed acrylic into the front groove At the footend close to the microswitch push down the sunbed acrylic Close the sash lock at the footend side Turn counter clockwise by 90 The sash lock pushes the sunbed acrylic into front groove ...

Страница 72: ...th lock and key against accidental reconnection Take a screwdriver and push in the spring at the slot in the front profile Protect the sunbed acrylic and the top canopy acrylic against scratches by putting a piece of styrofoam or some other soft padding material between top and sunbed acrylic Turn the profile outwards Lower the top canopy acrylic Two persons take the top canopy acrylic and take it o...

Страница 73: ...canopy acrylic If necessary clean the top canopy acrylic with a suitable acrylic cleaner Put the top canopy acrylic into the rear top canopy Tilt the top canopy acrylic upward Turn the top canopy profile outward until it snaps in ...

Страница 74: ...ts Do not replace HID lamps immediately after a tanning session Allow lamps and components to cool down completely prior to starting any maintenance work NOTICE Only replace HID lamps with lamps of the same type and wattage Refer to specifications on the type label Disconnect the uit from the mains supply system with the mains disconnection switch and secure with lock and key against accidental rec...

Страница 75: ...OF CUTS Defective or broken facial filter glasses can cause serious cuts Wear protective gloves Disassembly of facial filter Support the facial filter with one hand to prevent the filter glass from falling down during disassembly With a screwdriver push the holding bracket 1 to the footend side 2 The microswitch lifts the facial filter a bit forward ...

Страница 76: ... Do not dispose of HID lamps with regular waste Dispose of HID lamps in compliance with applicable environmental standards and regulations Dispose of defective or used HID lamps in compliance with applicable environmental standards and regulations ATTENTION During installation the new HID lamps can get damaged Never touch lamps with bare fingers Always use a clean dry lint free cloth ...

Страница 77: ...Only use original facial filters for replacement supplied by Advanced UV Light Installation of facial filter Replace defective facial filter by a new one Clean filter with a soft leather cloth slightly damped with glass cleaner or clear water Position the filter in such a way that the logo Original Dr Müller points towards you Take a screwdriver and push the bracket 1 to the footend side 2 Push the filt...

Страница 78: ...pter Assembly of rear column acrylic Replacement of dust filter mats The dust filter mats must be cleaned every 50 hours or earlier depending ambient conditions After 500 hours the dust filter mats need to be replaced or earlier pending ambient conditions CAUTION Risk of damage to the environment Dispose of dust filter mats in compliance with applicable environmental standards and regulations Dust filt...

Страница 79: ...rs Disconnect the unit from main supply with the mains disconnection switch and secure with lock and key against accidental reconnection Get a soft support ready for storage of the front cover Loosen the two screws at the front cover Slghtly lift the front cover and pull the holding brackets out of the slots in the bench supports Store the front cover on a soft support Lift the inmost grid for abo...

Страница 80: ...y with the mains disconnection switch and secure with lock and key against accidental reconnection Get a soft support ready for storage of the front cover Loosen the two screws at the front cover Lightly lift the front cover Pull the brackets out of the slots in the bench Store the front cover The backlighting lamp is now accessible and the lamp can be replaced Turn the backlighting lamp clockwise...

Страница 81: ...ion of the viewer Reassemble the front cover Put the brackets into the slots at the bench supports Push the front cover against the sunbed bench and tighten with screws Replacing of backlighting lamps in the top canopy The top canopy contains a backlighting lamp which highlights the acrylic insert in the top canopy To replace the backlighting lamp and or the starter proceed as follows Disconnect t...

Страница 82: ...y clean the backlighting lamp with a clean soft leather cloth damped with glass cleaner or clean water Put the backlighting lamp into the lampholder 3 Turn the backlighting lamp for about 90 counter clockwise 4 The backlighting lamp snaps into the holder Make sure that the stamp on the lamp points to the viewer Remove the top canopy support Push the top canopy cover into the front profile groove Ke...

Страница 83: ...nbed To replace the lamp and or the starter for the interior courtesy lamp proceed as follows Disconnect the unit from the mains supply with the mains disconnection switch and secure with lock and key against accidental reconnection Push the sunbed acrylic up 1 Lift the acrylic support 2 Lower the sunbed acrylic and let the sunbed acrylic rest on the acrylic support Turn the courtesy lamp clockwis...

Страница 84: ... clockwise 2 Set the new courtesy lamp into the lampholder 3 Turn the new courtesy lamp for about 90 clockwise 4 The new courtesy lamp snaps into the lampholder Lift the sunbed acrylic for about an inch Put the acrylic support back Let the sunbed acrylic down onto the sunbed ...

Страница 85: ...et a soft support for storage of the front cover ready Loosen the two screws at the front cover Lift the front cover for about an inch Pull the brackets out of the slots at the sunbed supports Store the front cover Turn off the lid from the new SunHaze cartridge Push the bracket at the SunHaze container down and hold 1 Take the used SunHaze container out of the SunHaze aroma system 2 Push the brac...

Страница 86: ...switch and secure with lock and key against accidental reconnection Remove front cover Get a soft support for storage of the front cover ready Loosen the screws at the front cover Lift the front cover for about an inch Pull the brackets out of the slots at the sunbed supports Store the front cover Take the condensation water container out of the sunbed Take off the lid of the container Empty the c...

Страница 87: ...and regulations Observe safety instructions and warning notices attached to the SunFresh system Inside the SunFresh container is a water purification system with a UV C lamp which keeps the water in the container germ free The purification unit with the lamp must be replaced after 6 000 operating hours or earlier if necessary CAUTION The UV lamp in the SunFresh system can get damaged when touched wi...

Страница 88: ...on unit Pull the plunge pipe out of the lid of the SunFresh container Store the plunge pipe clean and dust free CAUTION The function of the SunFresh system can be affected Use only distilled water for refill If necessary fill up the container with distilled water Fill up to the point where the straight wall of the containers ends and the upper convex swell begins Put the plunge pipe into the lid of ...

Страница 89: ...sensor 1 Connect the supply cable to the electrical connection socket for the SunFresh systemon the electric ballast tray Reassemble the front cover Put the brackets of the front cover into the slots of the sunbed supports Push the front cover against the sunbed bench and tighten screws ...

Страница 90: ... each use Spray the acrylics with a suitable acrylic cleaner Wipe dry with a clean soft lint free cloth Covers of sunbed and top canopy If necessary clean the surfaces of the sunbed and top canopy covers with a soft leather cloth slightly damped with clear water Wipe dry with a clean soft lint free cloth Lamps If necessary clean lamps with a soft leather cloth slightly damped with glass cleaner or...

Страница 91: ...Incorrectly performed disassembly work can cause serious and fatal injuries Only authroized seervice personnel and certified electricians are allowed to perform disassembly work CAUTION The sunbed components can get easily scratched Do not kick against components Do not scratch or damage surfaces for instance with tools WARNING HEAVY LOAD Carrying the heavy sunbed components can cause overstrain an...

Страница 92: ...isconnection switch Secure with lock and key against accidental or unauthorized reconnection Cover the unit with suitable material to protect against dust and dirt Re operation If you want to re operate the unit after an extended rest period remove the cover Clean the unit thoroughly Remove the lock and key and reconnect the unit to the mains supply system Perform daily check up as described in th...

Страница 93: ...ror messages Error code Possible cause and correction E01 Wind flag does not turn on Check wind flag and windflag terminal E02 Facial filter defective or missing Replace or assemble facial filter E03 Sunbed acrylic open Close sunbed acrylicn E04 Front cover open not assigned on all units Check front cover for correct fit E05 Emergency stop button activated optional Unlock emergency stop button E06 SunFr...

Страница 94: ...ent gets too hot Ventilation in the room fresh air supply and exhaust air disposal is not sufficient Cehck air openings and if necessary remove blockage One or more UV lamps in the top canopy or sunbed do not light up UV lamps not correctly installed into the lapholders Check installation of UV lamps UV lamp defective Replace UV lamp One or more HID lamps do not light up HID lamp defective Replace ...

Страница 95: ... Ruhrtalstraße 85 93 D 45239 Essen Phone 0049 201 8 49 12 0 Fax 0049 201 8 49 12 55 E Mail info auvl de Internet www auvl de Declaration of conformity Advanced UV Light Ruhrtalstraße 85 93 D 45239 Essen herewith declares that the product is in conformity with applicable safety standards and regulations according to EC stanadards Unit model type High performance sunbed model ICON46 Essen Standards ...

Страница 96: ...85 Warranty The warranty terms for this product by Advanced UV Light comply with the current legal provisions at time of purchase ...

Страница 97: ...86 ...

Страница 98: ...87 ...

Страница 99: ...88 ...

Страница 100: ...89 ...

Страница 101: ...90 ...

Отзывы: