10
Emergency Stop Button
ICON 46
46
•0
4 V
XT
In an emergency situation the sunbed can be switched off with the
Emergency Stop Button. UV-radiation stops immediately. The main cooling
turns off after a certain delay time (after-cooling time).
Push the Emergency Stop Button
- The unit stops, UV-radiation ceases immediately.
Lift the top canopy and leave the sunbed.
Inform operator of the sunbed that Emergency Stop Button has been
activated
Safety Features
Mains disconnection switch
The mains disconnection switch must be installed on the site. During breaks
of operation and after hours the mains supply must be disconnected with
the mains disconnection switch. The mains disconnection switch must be
secured against accidental activation.
The drawing shows a sample of a mains disconnection switch with lock and key.
Disconnection of mains supply
Turn the mains disconnection switch into position “O”
- The mains supply is disconnected
Secure mains disconnection switch against accidental reconnection
Put the lock into the opening of the switch.
Close the lock
Reconnecting the mains supply
Open the lock and remove
Turn the mains disconnection switch into position “I“.
- The mains supply is reconnected