Chapter 4: Configuration
1. Select
Networking > Wired Aux Ethernet
.
The Onboard Ethernet Settings screen is displayed:
Figure 4-2. Onboard Ethernet Screen
2. Select the
Server Mode
radio button under the IP Settings.
3. Enter a valid, available IP address for the Adept SmartFleet EX in the
IP Address
field.
Do not use the IP address: 1.2.3.4, because this would create a conflict with the IP
address permanently set for the Maintenance Ethernet port.
4. Enter the appropriate subnet mask for a host on your network in the
Netmask
field.
5. Enter the IP address of the default
Gateway
. (This is the IP address of the device used to
connect to your network, typically a router.)
6. Click
Apply
.
Adept SmartFleet EX User’s Guide, Rev. A