Chapter 2: Installation
1. Connect the AC plug of the power supply to AC power.
The power supply takes 100 – 240 VAC.
2. Plug the other end of the power supply into the 24 VDC plug on the Adept SmartFleet
EX.
NOTE
: The unit will start booting as soon as 24 VDC power is applied.
Chassis Grounding
The Adept SmartFleet EX is equipped with a chassis grounding point. See the following figure.
Adept recommends connecting a ground wire from the chassis ground point on the Adept
SmartFleet EX to earth ground. The ground wire must meet all local regulations.
NOTE
: This is not the same as the 24 VDC ground, on the front of the unit, which
is not used.
NOTE:
The maximum length for the ground wire for the Adept SmartFleet EX is 3
meters.
Grounding Point
Figure 2-3. Chassis Grounding Point
In many locations, the mounting and all terminations of the Adept SmartFleet EX must be per-
formed in accordance with local and national regulations to maintain regulatory compliance.
Adept SmartFleet EX User’s Guide, Rev. A
Page 19 of 54