![ADB Safegate CRE 10 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/adb-safegate/cre-10/cre-10_installation-manual_2847401016.webp)
16
A.07.370e - Edition 2.0
Description
3.3 Working principle
A Line input.
B Input filter. See § 3.5.2.
C Diode bridge and sensing PCB, components of the IGBT power bridge. See § 3.5.3.
D IGBT module and IGBT PCB, components of the IGBT power bridge. See § 3.5.3.
E Output filter. See § 3.5.5.
F Main transformer. See § 3.5.6.
G Output measure PCB. See § 3.5.7.
H Lightning arrestors. See § 3.5.8.
I
Circuit selector (optional). See § 3.6.3.
J Series output connection. See § 3.6.
K CPU PCB. See § 3.5.9.
L HMI. See § 3.7.
M Remote control PCB. See § 3.5.10.
N Power supply PCB. See § 3.5.11.
Legend
- Red lines: current
- Green lines: signal wires connections
- Black lines: low voltage connections
Current regulation
The equipment converts the single phase input voltage line into a rectified current and voltage. Then, the
equipment converts this DC current and voltage into a pure sine wave with a defined power rating.
Main feedback loop
The output measure PCB sends the measured output to the CPU PCB. Depending on the output, the CPU
PCB automatically generates a signal to adjust the regulation.
1
5
9
5
9
2
6
0
3
7
.
4
8
CANCEL
ON
REMOTE
OFF
ENTER
LOCAL
A
C
B
D
E
F
G
H
I
OUT
J
M
K
N
L
IN
Содержание CRE 10
Страница 1: ...A 07 370e Edition 2 0 Installation Manual Constant Current Regulator Type CRE ...
Страница 14: ...14 A 07 370e Edition 2 0 Safety ...
Страница 44: ...44 A 07 370e Edition 2 0 Inspection and transport ...
Страница 64: ...64 A 07 370e Edition 2 0 Installation ...
Страница 85: ...A 07 370e Edition 2 0 85 Technical data ...
Страница 86: ...adbsafegate com ...