![ADB Safegate CRE 10 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/adb-safegate/cre-10/cre-10_installation-manual_2847401036.webp)
36
A.07.370e - Edition 2.0
Description
3.6.3
Circuit selector (CS)
With a CS you can connect several (up to eight) series circuits to a single equipment.
The CS has two modes:
- Simultaneous: the equipment can connect to a number of the available circuits at the same time;
- Alternate: the equipment can connect to only one circuit at a time.
3.6.4
Lightning arrestors (option CS)
The additional lightning arrestors for the CS are installed on the
power output. The lightning arrestors are varistors.
A varistor is a surge protection device that is connected directly
across the AC output.
3.6.5
Interface PCB (PCB1702) (option CS)
The interface PCB is the remote control interface PCB of the
equipment, if the equipment has a CS.
3.6.6
CS PCB (PCB1619) (option CS)
The CS PCBs drive the CS relays through CANbus and measure
the current after the relay with a current sensor. (see § 3.6.10).
Note
This item is installed on the CS when the CS
option is chosen.
Note
This item is installed on the CS when the CS
option is chosen.
Note
This item is installed on the CS when the CS
option is chosen.
Содержание CRE 10
Страница 1: ...A 07 370e Edition 2 0 Installation Manual Constant Current Regulator Type CRE ...
Страница 14: ...14 A 07 370e Edition 2 0 Safety ...
Страница 44: ...44 A 07 370e Edition 2 0 Inspection and transport ...
Страница 64: ...64 A 07 370e Edition 2 0 Installation ...
Страница 85: ...A 07 370e Edition 2 0 85 Technical data ...
Страница 86: ...adbsafegate com ...