Installation
Connect - 1
1. Put the remote control wire (A) through the connector (B).
2. Strip the signal wires (C) approximately 100 mm.
3. Connect the signal wires to the terminal blocks. For the
connection scheme, see § 7.8.3.
4. Connect the earthing wire (D) to the earthing connector (E).
Connect - 2
1. Install the terminal blocks to the connector.
2. Make sure that the orientation of the terminal blocks corresponds with the illustration above.
3. Examine if the numbers on the connector correspond with the numbers on the female side on the
receiver of the remote connector.
4. Install the connector to the equipment.
5. Close the clamps of the connector.
6.13.2 Connect ethernet cable(s) (option)
1. Install the connector(s) to the ethernet connection(s).
6.13.3 Connect the multiwire cables to the interface PCB (PCB1702) (option CS)
1. Strip outer isolation from the remote control multiwire cable.
2. Pull the cable through the opening (A).
3. Connect the cable to the earthing bar. Use earthing
clamps (B).
4. Strip the inner isolation from the remote control cables.
5. Connect the wires to their WAGO connection point on the
interface PCB (C). For the connection scheme, see § 7.9.
To
connect the individual wires to the WAGO connectors, use
the specific tool delivered with the equipment.
6.14 Install lower rear panel
1. Connect the earthing wire and install the lower rear panel. See § 6.6.
C
A
B
D
E
C
A
B
Содержание CRE 10
Страница 1: ...A 07 370e Edition 2 0 Installation Manual Constant Current Regulator Type CRE ...
Страница 14: ...14 A 07 370e Edition 2 0 Safety ...
Страница 44: ...44 A 07 370e Edition 2 0 Inspection and transport ...
Страница 64: ...64 A 07 370e Edition 2 0 Installation ...
Страница 85: ...A 07 370e Edition 2 0 85 Technical data ...
Страница 86: ...adbsafegate com ...