18.
Repeat Steps 16 and 17 with your replacement library.
19.
With assistance, slide the replacement library enclosure onto the metal rails thet are alredy
in position in the rack.
20.
Tighten the mounting bracket screws to anchor the replacement library enclosure to the
rack.
21.
Plug in the power cord and host interface cable into the replacement library enclosure.
22.
Power on the library.
23.
Run the Library Verify test (
refer to OCP “Service: Library Verify”).
24.
Securely package the library enclosure that was replaced, and return to repair center.