Make sure the library and tape drive are on their own SCSI bus and
not daisy-chained to another tape drive or to the hard drive being
backed up.
Make sure the library is connected to a LVDS SCSI bus and there
are no SE devices on the same bus, because this will cause the
entire bus to negotiate down to SE speed.
Use an Ultra320 SCSI bus and high-quality cabling with the library.
Do not connect the library to a narrow SCSI bus.
Bad performance
Try a new cartridge. A marginal cartridge can cause performance
problems due to bad spots on the tape requiring retries.
Backing up data that compresses poorly or is already compressed
will lower performance.
Check the size of the files. Small file size can impact performance.
Confirm that the backup application is utilizing block sizes of at least
32KB, preferably 64KB. Refer to the backup application
documentation for details.
Check the network bandwidth from the host computer. If you are
backing up data over a network, consider comparing to a local-only
backup.
Make sure the backup server has enough memory to handle the
bandwidth of the backup or restore.
Clean the tape drive. See ”
Cleaning the tape drive
” on page 57 for
instructions.
Media Attention LED Issues
Contamination by loose
debris.
Avoid contamination by ensuring that the library is installed in a clean,
contamination-free environment. Cartridges should be stored vertically in
their plastic cases. Continue cleaning the tape drive as needed.
Non-acclimated media
A cartridge should be acclimated for at least 24 hours before being used,
particularly if it has been stored at a substantially different temperature
or level of humidity than the library.
Cartridge is incompatible
Use only cartridges that are compatible with the drive type.
Make sure you are using an Ultrium universal cleaning cartridge.
(See ”
Cleaning the tape drive
” on page 57.)
Expired cleaning cartridge
A cleaning cartridge is good for Ultrium universal librares: 50 cleans
Bad/defective/contaminated
media
If the Media Attention LED is cleared and
–although the drive has been
cleaned - immediately re-displays each time a particular cartridge is
reloaded that cartridge should be suspected as being defective.,
Export the cartridge and load a known good cartridge. In some
cases, a cartridge can be worn out, have a defective Cartridge
Memory, or have been formatted as a Firmware Upgrade Cartridge.
Any cartridge that is suspected of being defective or contaminated
should NOT be reused in any drive.
Содержание actiLib Autoloader 2U
Страница 1: ...actiLib Autoloader 2U User and Service Guide Date September 17 2009 ...
Страница 10: ...Figure 63 Releasing the magazine 73 ...
Страница 21: ...Figure 9 Shipping lock before transportation 3 4 5 2 1 ...
Страница 31: ...5 7 OCP Menu Flow Charts Figure 17 OCP User interaction Mode actiLib Library 2U ...
Страница 32: ...Figure 18 Interaction Mode Information ...
Страница 33: ...Figure 19 Interaction Mode Information continuation ...
Страница 34: ...Figure 20 Interaction Mode Commands ...
Страница 35: ...Figure 21 Interaction Mode Configuration ...
Страница 36: ...Figure 22 Interaction Mode Configuration continuation ...
Страница 37: ...Figure 23 Interaction Mode Service ...
Страница 43: ...Figure 28 Slot numbering right magazine ...