6                                                                                                                                       NEUROPROBE

®

 500 PRO USER MANUAL 

 

 

COPYRIGHT © 2006 - 2017, ACCELERATED CARE PLUS CORP., ALL RIGHTS RESERVED 

 ELECTROTHERAPY/INFRARED WARNINGS & PRECAUTIONS  

 

CAUTION:  Federal  law  restricts  this  device  for  sale  or  use  by,  or  on  the  order  of,  a  Practitioner 
licensed by the laws of the state in which he/she practices to use or order the use of the device. 
 
Please  note  that  Accelerated  Care  Plus  cannot  provide  medical  advice.  If  you  have  specific 
medical questions, please contact your healthcare professional. 

 

Electrotherapy Warnings 

 

The long-term effects of electrical stimulation are unknown; 

 

Do not apply stimulation over the patient’s neck because this could cause severe muscle spasms resulting in 
closure of the airway, difficulty in breathing, or adverse effects on heart rhythm or blood pressure 

 

Do not apply stimulation across the patient’s chest because the introduction of electrical current into the chest 
may cause rhythm disturbances to the patient’s heart, which could be lethal.  Stimulation should not be applied 
transthoracically in the vicinity of the heart, as introduction of electrical current into the heart may cause cardiac 
arrhythmias. 

 

Do not apply stimulation when the patient is in the bath or shower 

 

Do not apply stimulation while the patient is sleeping; and 

 

Do not apply stimulation while the patient is driving, operating machinery, or during any activity in which 
electrical stimulation can put the patient at risk of injury. 

 

Consult with the patient’s physician before using this device because the device may cause lethal rhythm 
disturbances to the heart in susceptible individuals 

 

Apply stimulation only to normal, intact, clean, healthy skin. 

 

Do not operate this device until the User Manual, including all Indications for Use, Contraindications, Warnings 
and Precautions, have been carefully read and understood. 

 

Operation of this device or placement of lead wires, probes, pads and electrodes in close proximity (less than 5 
feet) to an operating shortwave or microwave diathermy unit may produce instability in the device output or 
burns at the treatment site.   Lead wires and device can pick up the magnetic field output of the diathermy and 
through induction convert it into an electrical field, transmit the energy into the patient increasing the current 
density at the electrodes of applicators.  Since the patient may not feel the 27 MHz frequency, they lack the 
protective sensation and tissue burns could result.  Short-wave field could potentially damage or reset medical 
devices in close proximity to the drum applicator. 

 

Treatment should not be applied over the carotid sinus nerves, (located in the anterior neck triangle), including, 
stellate ganglion, vagus nerve, or laryngeal or pharyngeal muscle.   Particular care should be taken for patients 
with a known sensitivity to the carotid sinus reflex, as carotid sinus stimulation may alter blood pressure and 
cardiac contractility. 

 

Do not apply treatment over testes, heart or eyes.  Electrical stimulation may affect organ function. 

 

Do not apply over or in close proximity to active cancer (except in terminal / palliative / hospice care), as 
therapy may increase blood flow to the tumor. 

 

Treatment should not be applied when high fever is present over swollen, severe infection (osteomyelitis, 
sepsis, tuberculosis, etc.) or inflamed areas/skin eruptions (phlebitis, thrombophlebitis, varicose veins, etc.). 

 

Do not apply over the lumbar or abdominal region, or over the uterus during pregnancy (to prevent uterine 
contraction), or during menstruation as therapy may temporarily increase menstrual flow. 

 

Treatment  should  not  be  applied  transcranially.

  Since  the  effects  of  stimulation  of  the  brain  are  unknown, 

stimulation should not be applied across the head, and electrodes should not be placed on opposite sides of the 
head; 

 

Stimulation should not be applied to patients connected to patient monitoring equipment, as the stimulation may 
have an effect on the proper operation of the monitoring equipment. 

 

Stimulation should not be applied directly over external stimulator systems with lead wires 

Содержание 140500B

Страница 1: ......

Страница 2: ...al may not be used for any other purpose Any additional copies of the Manual shall be ordered from ACP No changes or modifications shall be made to the Manual without prior review and written authoriz...

Страница 3: ...rapeutic Ultrasound Pulsed Shortwave Diathermy devices and advanced Therapeutic Exercise Systems Our MEGAPULSE NEUROPROBE OMNISTIM OMNISOUND OMNICYCLE OMNIVR OMNISTAND OMNIVERSA OMNISWD and SYNCHRONY...

Страница 4: ...cuments Caution electrical precautions Remote Control connection CE mark of confidence compliant to MDD 93 42 EEC Connection Electrode Cable IP2X Classification against intrusion of water dust acciden...

Страница 5: ...STIMULATION Optional 15 TREATMENT GUIDELINES 16 Introduction to Medium Frequency Currents 16 Electrode Application Techniques 17 SLD Infrared Pad Application Techniques 19 Treatment Preparation 19 INF...

Страница 6: ...frared spectrum to provide topical heating for the purpose of elevating tissue temperature for Temporary relief of minor muscle and joint pains Minor arthritis pain and muscle spasm Relieving stiffnes...

Страница 7: ...ximity less than 5 feet to an operating shortwave or microwave diathermy unit may produce instability in the device output or burns at the treatment site Lead wires and device can pick up the magnetic...

Страница 8: ...s are not advised for use with OmniVersa Omnistim Systems When cleaning the device never immerse them or wash them with water See the infection control section in this manual for cleaning instructions...

Страница 9: ...n Establishment of acceptable intensity levels for desensitized areas may be related to the intensity levels tolerated on normal skin in opposite or related body parts Caution should be used in the pr...

Страница 10: ...on of an Estim probe Interferential Current in bipolar or quadripolar modes or Monochromatic Infrared Therapy to reduce pain and increase circulation Flexible neoprene pads deliver heat and Infrared t...

Страница 11: ...selected Time remaining Carrier Frequency Bar graph for Vector and detection modes Button speeds and delay Vector selection Output current Display contrast Sweep rate and modulation selection E LEAD...

Страница 12: ...output or stop the treatment START STOP also cancels the SET mode Q LED for Point Stimulation Probe output indicator R LED indicating unit is connected to line power Factory Settings The Neuroprobe 5...

Страница 13: ...xtremity SLD Infrared Pad Plug it into the probe output socket Apply the SLD Infrared Pad to the treatment area Use an infection control cover over the SLD Infrared Pad and proper infection control pr...

Страница 14: ...he treatment current is switched off and INFRARED THERAPY is displayed Turn off the unit by pressing the POWER button 1 5 IFC Therapy with Pad Electrodes Press the POWER button 1 5 to turn on the Neur...

Страница 15: ...Note that for all IFC or INFRARED PAD protocols the treatment time is preset but may be adjusted at will during the treatment Once the treatment is completed remove the electrodes from the patient an...

Страница 16: ...probe or from the output A control on the panel The stim light on the probe turns on when the unit is in stimulation mode and shuts off during detection mode The treatment is complete when all of the...

Страница 17: ...r or in Quadripolar Interferential mode for patient treatment With medium frequency currents the energy of each individual pulse is low providing for stimulation of only one or two neurons Since the p...

Страница 18: ...arious areas of the body Electrode placement is dependent on the etiology of the condition Monopolar Mono Polar Technique This technique may use two electrodes of different sizes however one is in the...

Страница 19: ...other CERVICAL BIPOLAR PLACEMENT OF ELECTRODES IFC Quadripolar Quadri Polar Technique This technique requires the use of two output channels and four electrodes usually but not exclusively of the same...

Страница 20: ...n indication of increased current density under part of or the entire electrode surface In this case immediately start to reduce the current intensity to zero remove the electrodes to inspect the surf...

Страница 21: ...gelled or self adhering electrodes all increase the risk of irritation or burns and are contraindicated for use with Neuroprobe Systems Lead Wires Inspect the full length of the lead wires for signs...

Страница 22: ...sure to blood body fluids containing blood semen and vaginal secretions is likely to occur Health care workers with exudating lesions or weeping dermatitis should refrain from all direct patient care...

Страница 23: ...reased risk of patient cross contamination The following are the recommended practices After each use clean common contact surfaces such as control panel and lead wires with ACP germicidal wipes With...

Страница 24: ...assessment tools cart handles etc 7 Set up the patient per guidelines for the procedure 8 Provide treatment as appropriate 9 Discard all disposables 10 With clean gloves remove the plastic film from...

Страница 25: ...PADS NERVE BLOCK Symptomatic relief of pain from localized dermal or segmental origin 5000Hz Continuous Treatment time of 15 minutes Block pain by causing temporary nerve block via reactive depolariza...

Страница 26: ...e and the red wires in the opposite phase relative to each channel All variable parameters may be altered during operation I SENSORY MOTOR PROBE TREATMENT PROTOCOLS The Sensory Motor protocols contain...

Страница 27: ...onal electrotherapy approaches Its primary application is in the reduction of pain and in the stimulation of increased blood flow in the deeper tissues and muscles The following pads programs are avai...

Страница 28: ...0 seconds 0 20 Seconds Beat Sweep Rate Scan Time Modulation ON ON or OFF Vector Auto Intensity 0 0 20 Treatment time 30 minutes 0 99 Minutes Waveform Burst Alternating Current Output 0 mA 0 99 mA PADS...

Страница 29: ...y be varied during operation and saved by the user The following program is available in Noxious Probe mode PROBE NOXIOUS Sensory Noxious Waveform PARAMETER DEFAULT VALUES RANGE OF USER ADJUSTABLE VAL...

Страница 30: ...USER ADJUSTABLE VALUES Carrier frequency 5 0 KHz Stim time 60 Seconds 0 999 Seconds Waveform Alternating Current Output 0 mA 0 2 25 mA II NERVE BLOCK PADS AND SLD INFRARED PAD PROTOCOL The Nerve Block...

Страница 31: ...if the lead wire passes the test LED will be red if the lead wires are faulty and need to be replaced see Figure 7 below Remove electrode s and replace if necessary Adjust output up or down as necess...

Страница 32: ...d INSPECT POWER SUPPLY OPERATION 1 Connect the power cord to the power supply and to a power outlet 2 Connect the power supply cable to the stimulator unit Figure 4 Figure 4 3 Press the power supply s...

Страница 33: ...ceptacle labeled LEAD WIRE TESTER When the POWER is on green LED will turn on if the lead wire passes the test LED will be red if the lead wires are faulty and need to be replaced Figure 7 Service Cen...

Страница 34: ...S RESERVED For repair or service of ACP Products and accessories please call 800 350 1100 and follow the prompts Normal hours of operation are 6 00am to 5 00pm Pacific Standard Time After hours please...

Страница 35: ...r Scans amplitude of channel A from 0 maximum every 10 seconds relative to channel B which varies concurrently out of phase Slow 90 Scans amplitude of channel A from 0 maximum every 60 seconds relativ...

Страница 36: ...conductivity PATIENT SAFETY SYSTEMS Activation By patient safety hand control which shuts down output Output modality may not be changed during operation Output levels are reset to zero at the start a...

Страница 37: ...ptional probe IFC and SLD Infrared Pad treatments Shipping Weight 4 lbs 1 8 kg ITEM ITEM NO DESCRIPTION 48758 Lead Wire Blue Green Coded plug in 7 214cm 080 tip pin stereo plug 55055 Grounding Pad 3x4...

Страница 38: ...stim Electrodes 4ea pkg 10pkg bx 61227 2x4 Multi use E stim Electrodes 4ea pkg 10pkg bx 26854 3x5 Multi use E stim Electrode 2ea pkg 10pkg bx SINGLE USE ELECTRODES 28303 2x2 Single use E stim Electrod...

Страница 39: ...trol of Touch Operatory Surfaces 4 x 6 Clear Perforated Sheets 1200 sheets roll 50593 Barrier Film for Infection Control of Infrared Therapy Pads 12 x 14 Perforated Sheets 800 sheets roll 63574 Barrie...

Страница 40: ...oid if any of the following have occurred 1 The product contains repairs or replacement parts not furnished by ACP 2 The product is damaged resulting from misuse or negligence 3 The product has been t...

Страница 41: ...ed repair is deemed to be under warranty ACP is not responsible for any loss or damage to the Equipment prior to receipt at the ACP Service Center Equipment returned for warranty service must be shipp...

Страница 42: ......

Отзывы: