-8-
HIGH ELEVATIONS
This appliance may be installed at higher altitudes. Please refer to National Fuel Gas Code ANSI Z223.1/NFPA 54,
CSA-B149.1 Natural Gas and Propane Installation Code, local authorities, or codes having jurisdiction in you area
regarding derate guidelines.
US Installations - Refer to the American Gas Association guidelines for the gas designed appliances derating
method. For elevations above 2,000 ft (610 m), input ratings are to be reduced by 4% for each 1,000 ft (305 m)
above sea level.
Canadian Installations - When the appliance is installed at elevations above 4,500 ft (1,372 m), the certified high
altitude rating shall be reduced at the rate of 4% for each additional 1,000 ft (305 m).
Part Overview
Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping
damage and immediately inform your authorized dealer if any damage is found. Do not install any damaged,
incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received.
AA BATTERIES
(4 PACK)
REMOTE
9V BATTERY
BOX
AAA BATTERIES
(3 PACK)
Gas Pressures
Natural Propane (LP)
Inlet Minimum
5.0” w.c.
12.0” w.c.
Inlet Maximum
10.5” w.c.
14.0” w.c.
Manifold Pressure 3.8” w.c.
11.0” w.c.
Gas Specifications & Orifice Size
Fuel Max. Input
BTU/h
Min. Input
BTU/h
Orifice
Size
Nat.
18,500
10,000
#45
LP
17,000
9,000
3/64”
Natural Gas
LP Gas
WARNING: This appliance must be vented to the outside. The venting system must NEVER be attached to
a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a separate vent
system. Do not use common vent systems.
WARNING: Do not pack the open air spaces with insulation or other materials. This could cause high temperatures
and may present a fire hazard and serious injury, property damage or loss of life. Operation of improperly
installed and maintained venting system could result in serious injury, property damage or loss of life.
WARNING: Read all instructions completely and thoroughly before attempting installation. Failure to do so
could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained
venting system could result in serious injury, property damage or loss of life.
Existing Fireplace Requirements
APPLIANCE PLACEMENT CONSIDERATIONS
•
This fireplace insert must be installed on a level surface capable of supporting the fireplace insert and venting.
•
This fireplace insert may be installed in a bedroom.
•
Please be aware of the large amount of heat this fireplace insert will produce when determining a location.
EXISTING FIREPLACE SPECIFICATIONS
•
Any smoke shelves, shields, and baffles may be removed if attached by mechanical fasteners. If necessary,
remove firebrick to obtain at least the minimum opening requirements.
•
Cutting of any sheet metal parts of the existing fireplace is prohibited.
•
If the metal floor is removed, the insert must be placed directly on metal base of metal fireplace. Mechanically
attach “THIS UNIT HAS BEEN MODIFIED” label at bottom of existing firebox so it will be visible if this gas fireplace
insert is removed.
WARNING: Due to high surface temperatures, the fireplace insert should be located out of traffic and away
from furniture and draperies.
CAUTION: Adequate accessibility clearances for servicing and proper operation must be maintained.
NOTE: Failure to follow these instructions will void the warranty.