-27-
Adjustment
PRESSURE TESTING
NOTE: The fireplace and its main gas valve must be disconnected from the gas supply piping system during any
pressure testing of the system at test pressures in excess of 1/2 psi (3.5 kPa).
CHANGING THE BATTERIES IN MY REMOTE CONTROL?
When the remote-control batteries are low, a battery icon will appear on the LCD display of the remote control
before all battery power is lost. When the batteries are replaced, this icon will disappear.
WHY DID MY THERMOSTAT DISAPPEAR FROM MY REMOTE?
When reinstalling batteries, the thermostat may have been pressed while the batteries were changed. To make
your thermostat reappear, follow these steps:
1. Remove one battery.
2. Press and hold the thermostat button on the remote.
3. Reinstall the battery while holding the thermostat button down.
4. If you see “set”, the thermostat button is now enabled.
5. If you see “clear”, the thermostat button is disabled.
6. Repeat this procedure if you did not see “set” or “clear” to add/remove the thermostat option.
WHY WON’T IT TURN ON?
If your remote control is working, but your fireplace won’t turn on, it may be in “lockout” mode. To reset a lockout
follow these steps:
1. Turn off remote.
2. Turn on remote and wait 2 seconds.
3. Turn off remote and wait 2 seconds.
4. Turn on remote and wait 2 seconds.
5. Turn off remote.
This should clear the lockout mode. Turn on the remote and start the fireplace. Ensure the master switch is in the
“ON” position. If the lockout mode is still on, follow these steps:
1. Turn off the remote.
2.
If you see the snowflake icon, press the Mode button and toggle it to IPI mode.
3. Shut off AC power to the ignition control module (shut off breaker).
4. Toggle master switch to off. Wait 30 seconds.
5. Turn on AC power by turning on breaker.
6. Turn on remote, then turn off remote.
7. Toggle master switch back on.
8. Press Mode button on remote. Select CPI mode to reignite the pilot. After pilot lights, turn on your remote to
ignite.
After completing these steps, contact your authorized dealer if it won’t turn on.
CAUTION: Pressure check taps for manifold (outgoing) and inlet (incoming) pressure have been incorporated
into the valve. The pressure tap marked OUT measures outgoing pressure. The pressure tap marked “IN”
measures incoming pressure.