-16-
3.
Lift glass assembly up and off of the (2) tabs located at the top of the firebox.
INSTALL GLASS ASSEMBLY
1.
Align the slots on top of the glass assembly over the tabs at the top of the firebox while lowering the bottom
of the glass assembly into position. NOTE: The glass may have to be tilted in order for the latches to properly
hook onto the glass.
2.
Pull the spring-loaded latches out and up to secure the bottom of glass to the bottom of the fireplace.
Control Board
Electrical Information
ELECTRICAL GROUNDING INSTRUCTIONS
This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and
should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding
prong from this plug.
WIRING REQUIREMENTS
• The IFC System Module requires 120V of electricity and/or batteries to operate.
• Using the battery back-up will operate the burner only.
• Light and blower components will not function on battery back up power.
CAUTION: Check all connections for leaks with soapy water, whether field or factory made.
WARNING: Do not use this fireplace if any part has been under water. Immediately call a qualified service
technician to inspect this appliance and to replace any part of the control system and any gas control which
has been under water.
WARNING: Electrical Grounding Instructions: This appliance is equipped with a three-prong (grounding) plug
for your protection against shock hazard and should be plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong from this plug.
WARNING: If burner and/or pilot have been burning, use appropriate protection to avoid burns or damage to
personal property before removing any components. DO NOT OPERATE THIS APPLIANCE WITHOUT THE SEALING
GASKET (LOCATED UNDER THE CONTROL BOARD) IN PLACE. IF GASKETING IS DAMAGED, IT MUST BE REPLACED.