-13-
CONNECT VENT PIPE TO AIR DUCT
1. Place previously removed air duct into existing
fireplace opening.
2. Connect exhaust vent pipe to exhaust collar on air
duct. Apply a bead of high temperature sealant
around exhaust pipe and slide inside. Secure with
three (3) 1/2” (13 mm) self-tapping screws. Apply
additional high temperature sealant around join to
ensure an air tight seal.
3. Connect air intake vent pipe to air duct. Apply a
liberal bead of high temperature sealant around
intake on air duct. Slide on the combustion intake
pipe and secure with three (3) 1/2” (13 mm) self-
tapping screws. Apply additional high temperature
sealant around joint to ensure an air tight seal.
4. Visually check vent pipe connection to air duct.
NOTE: This appliance is approved to be vented
using DuraVent, BDM, ICC, Olympia venting
components, and Metal Fab.
PLACE AND SECURE APPLIANCE
1.
Slide the gas fireplace insert into existing fireplace
opening until the channels on top of the appliance
are aligned with the air duct.
2. Insert the air duct pull rod handle through access
slot at the top of appliance and place pull handle
hook through the hole in pull rod. Simultaneously
push the gas insert into existing fireplace and pull
the air duct forward until seated.
3. Secure air duct to appliance by using slots at the
top of the appliance to secure with two (2) 1/2” (13
mm) sheet metal screws.
4. Use the pull rod handle to pull the air duct back to
starting position. Remove pull handle. Verify vent
system connection.
5. If necessary, level the gas insert by threading
leveling bolts into nuts at the bottom of the insert (2
each side). Verify appliance is properly positioned.
Air Duct in Existing Fireplace
AIR DUCT
ALIGNED
GAS INSERT
Aligned Gas Insert in Existing Fireplace
FLEXIBLE PIPES
SHEET METAL
SCREWS (3 TOTAL)
SEALANT
SEALANT
Secured Vent Pipes to Air Duct
Seated Air Duct
PULL ROD
SECURE WITH
(2) SCREWS
(shown without venting attached for clarity purposes only)
CAUTION: Proper operation of this appliance requires exhaust and combustion air pipes to be connected to
the correct collar, on both the termination kit and the gas fireplace insert air duct.